Installation
312
8.
INSTAL
LAT
ION
In
ductive compon
ents
276
DDS
HARDWARE
Ref.1310
8.2 Inductive components
Installing the DDS system requires certain precautions regarding the con-
nection of the inductive components such as contactors, relays, electro-
valves, motor brakes or, in general, any type of coil.
Hence:
All inductive circuits or components must have their own interference
suppressor that must be installed as close as possible to the inductive
component.
The mentioned interference suppressors will be RC circuits, varystors
or suppressor diodes.
The excitation cables of the inductive components and the signal cables
must not run in the same channel especially when not using shielded
cables for these signals. A typical scenario is when using inductive
proximity switches or similar usually connected with an unshielded ca-
ble.
In extreme situations and if the sensors used on the machine are very
sensitive to the interference conducted through the supply cables (24 V
DC), it may be necessary to isolate or decouple them from that of the
supply of the system elements (inductive components, drives, etc.).
MANDATORY.
Do
not
use
fly diodes
as interference suppression ele-
ments for inductive components. These diodes can only serve as interfer-
ence suppressor of the inductance due to the cabling itself.
Summary of Contents for APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1310...
Page 6: ...I 6 DDS HARDWARE Ref 1310...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...16 Ref 1310 DDS HARDWARE...
Page 30: ...1 DESCRIPTION 30 Description DDS HARDWARE Ref 1310...
Page 94: ...2 POWER SUPPLIES 94 Power supplies DDS HARDWARE Ref 1310...
Page 188: ...3 DRIVE MODULES 188 Drive modules DDS HARDWARE Ref 1310...
Page 204: ...4 AUXILIARY MODULES 204 Auxiliary modules DDS HARDWARE Ref 1310...
Page 232: ...SELECTING CRITERIA 5 232 Selection criteria DDS HARDWARE Ref 1310...
Page 266: ...7 CABLES 266 Cables DDS HARDWARE Ref 1310...
Page 312: ...8 INSTALLATION 312 Installation DDS HARDWARE Ref 1310...
Page 326: ...9 FUNCTIONAL SAFETY 326 Functional safety DDS HARDWARE Ref 1310...
Page 354: ...10 CONNECTION DIAGRAMS 354 Connection diagrams DDS HARDWARE Ref 1310...
Page 378: ...12 SALES REFERENCES 378 Sales references DDS HARDWARE Ref 1310...
Page 384: ...13 COMPATIBILITY 384 Compatibility DDS HARDWARE Ref 1310...
Page 385: ......