02/05/2020
37
SERVICE MANUAL
CONVEYOR BELT
DISHWASHERS
The system is adjusted using springs (1 or 2) mounted on the
module where the drive motor is located.
A spring and screw are supplied with the appliance.
Locate the module where the drive motor is mounted and remove the
corresponding lower front panel.
First remove the panel fastening bolts and lift the door.
Turn the front panel slightly upwards at the lower part and then
remove.
Locate the existing spring and mount the new spring in the adjacent
space. The spring which is now mounted can be released to make
the task easier.
Take care not to over-tighten the bolts and break or
damage the safety lock detector switch (see circle in image below).
VERY
IMPORTANT
:
the springs must be compressed to a length of
44 mm.
IMPORTANT: The springs must be compressed to a length of 44 mm in order to function
correctly.
This is the interior measurement. The thickness of the plates must be added if measuring
the outer part.
Summary of Contents for CCO-180
Page 1: ...CONVEYOR DISHWASHERS Service Manual SERVICE MANUAL CONVEYOR DISHWASHERS 02 05 2020 ...
Page 13: ...02 05 2020 12 SERVICE MANUAL CONVEYOR BELT DISHWASHERS 11 USE ...
Page 19: ...02 05 2020 18 SERVICE MANUAL CONVEYOR BELT DISHWASHERS 15 TECHNICAL DATA ...
Page 20: ...02 05 2020 19 SERVICE MANUAL CONVEYOR BELT DISHWASHERS ...
Page 57: ...02 05 2020 56 SERVICE MANUAL CONVEYOR BELT DISHWASHERS ...
Page 67: ...02 05 2020 66 SERVICE MANUAL CONVEYOR BELT DISHWASHERS ...
Page 71: ...02 05 2020 70 SERVICE MANUAL CONVEYOR BELT DISHWASHERS ...
Page 75: ...02 05 2020 74 SERVICE MANUAL CONVEYOR BELT DISHWASHERS 36 ELECTRICAL DIAGRAM ...
Page 76: ...02 05 2020 75 SERVICE MANUAL CONVEYOR BELT DISHWASHERS ...