02/05/2020
73
SERVICE MANUAL
CONVEYOR BELT
DISHWASHERS
35.3.
ENERGY RECOVERY SYSTEM
-
The energy recovery fan absorbs the steam generated inside the tunnel and sends the condensed water to the
machine tub, increasing the water temperature.
-
It permits savings of up to 3 kW-h.
-
Recommended for dishwashers with cold water inlet (CW) and temperatures of less than 25 ºC. It should not
be installed in machines with hot water inlet, or in ECO models with heating of the rinse water in the GWB-40
generator.
CRS-600
in COMPACT models:
•
Module with feed system included.
•
Mounted at the entrance.
CRS-700
in MODULAR models:
•
Mounted on the high part of the dishwasher.
•
Does not increase length.
•
Should be used with drying tunnel.
•
The CRS-700 energy recovery fan is placed over the rinse module.