E
XAMPLE
MANUAL
19
Operation 3 (Facing and outside turning)
G95 G96 F0.2 S180 M4
T2 D2
G0 X90 Z20
G1 X78 Z5
G1 Z-40
G1 X85
G0 Z0
G1 X66
G1 Z5
G1 G42 X72 Z1
G1 X80 Z-3
G0 G40 Z150
Second fixture:
Set new part zero
(MSG “* NEW FIXTURE - REVERSE PART *”)
M0 M5
(MSG “”)
(ORGX54=0, ORGZ54=80)
G54
G92 S2200
Operation 4 (Outside arc turning)
G95 G96 F0.2 S180 M4
T2 D2
G0 X90 Z20
G1 G42 X84 Z5
G84 X0 Z0 Q78 R-48.775 C2 L0.3 M0.3 H0.1 I-11 K-48.775
G0 G40 Z150
M30