ꞏ67ꞏ
R
EF
. 2107
Error 4: Physical error in the internal bus of the node.
Error 5: Internal-bus initializing error.
Type.
Description.
Solution.
- - -
Communication error at the bus or the bus is
interrupted.
Replace wrong module. Place an I/O module after
the leading module and check if it causes an error.
If there are no errors, replace the leading (first)
module.
If the leading module is correct, replace the wrong
I/O module. To locate the wrong module, repeat
the following sequence as often as necessary.
• Remove power from the node, place the end
module in the middle of the node and apply
power to the node again.
• If the error persists, remove power from the
node again, place the end module in the
middle of the first half of the node and apply
power to the node again.
• If there are no errors, remove power from the
node again, place the end module in the
middle of the second half of the node and
apply power to the node again.
If there is only one I/O module left in the node, that
module or the leading module will be the wrong
one.
n
The bus is interrupted after the n-th module.
The number of blinks indicates the n position of
the I/O module.
Remove power from the node, replace the
(n+1)th module and apply power to the node
again.
Type.
Description.
Solution.
n
Communication error while initializing the
module.
The number of blinks indicates the n position of
the I/O module.
Remove power from the node, replace the n-th
module and apply power to the node again.
Summary of Contents for CNC 8065elite T
Page 1: ...Ref 2107 8058 8060 8065 8070 CNCelite Remote modules RIO5 RIOW and RIOR series...
Page 6: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 6 REF 2107...
Page 12: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 12 REF 2107...
Page 14: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 14 REF 2107...
Page 18: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 18 REF 2107...
Page 20: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 20 REF 2107...
Page 22: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 22 REF 2107...
Page 24: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 24 REF 2107...
Page 125: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 125 User notes REF 2107...
Page 126: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 126 User notes REF 2107...
Page 127: ...Remote modules RIO5 RIOW and RIOR series CNCelite 8058 8060 8065 8070 127 User notes REF 2107...