Hardware configuration.
CNC 8070
CEN
T
RAL UNIT + MONITOR (Q7-A
PLATFORM).
6.
Conn
ecti
ons.
·131·
(R
EF
: 1911)
6.8.11
CAN bus.
CANopen is a network communication protocol based on the CAN bus system for connecting
the CNC with remote modules and keyboards. The CAN connection supports up to 32
devices (nodes), including the central unit; more one than keyboard and several groups of
remote modules are possible.
CAN connector.
The cable shield must be connected to the connector at both ends. The connector has two
shield pins. Both pins are equivalent; the CAN shield may be connected to either one.
Characteristics of the CAN cable.
Use a specific CAN cable. The ends of all the wires and the shield must be protected by the
corresponding terminal (pin). Also use the terminals (pins) to secure the cable to the
connector.
CAN bus with CNC (master) and RIOR modules.
Characteristic.
Description.
Type.
Shielded. Twisted pair (1 x 2 x 0.22 mm²).
Flexibility.
Extremely flexible. Minimum bending radius, static = 50 mm and
dynamic = 95 mm.
Cover.
PUR
Impedance.
Cat.5 (100
- 120
)
Master
Node 1
Node 2
CAN bus.
B28
B28A
B28B
B28A
B28B
Node n
Plug-in part. 5-pole Phoenix-contact minicombicon connector (3.5 mm
pitch).
Pin.
Signal.
Function.
1
GND
Ground / 0 V.
2
CL
(LOW) bus signal.
3
SH
CAN shield.
4
CH
(HIGH) bus signal.
5
SH
CAN shield.
Summary of Contents for CNC 8070
Page 1: ...Ref 1911 8070 CNC Hardware configuration...
Page 8: ...BLANK PAGE 8...
Page 14: ...BLANK PAGE 14...
Page 18: ...BLANK PAGE 18...
Page 22: ...BLANK PAGE 22...
Page 24: ...BLANK PAGE 24...
Page 26: ...BLANK PAGE 26...
Page 28: ...Hardware configuration CNC 8070 1 PREVIOUS INFORMATION 28 REF 1911...
Page 94: ...Hardware configuration CNC 8070 6 CENTRAL UNIT MONITOR Q7 A PLATFORM 94 REF 1911 C70 15AT...
Page 273: ...Hardware configuration CNC 8070 273 User notes REF 1911...
Page 274: ...Hardware configuration CNC 8070 274 User notes REF 1911...
Page 275: ...Hardware configuration CNC 8070 275 User notes REF 1911...