8.4
Dimensions and characteristics of the enclosure.
8.4.1
Enclosure design.
The enclosure must meet the following requirements:
• Keep the enclosure clean. If the enclosure has ventilation holes, anti-dust filters should
be installed in all of them.
• Reserve some room for the laying out cables in the connector area. This space must allow
for the connection of cables, while accounting for their bending radius.
• The cabinet must consider the minimum recommended distances between the enclosure
walls and the hardware to let the air flow and improve heat dissipation.
Dimensions of the cut off part and the enclosure.
To meet the previous requirements, Fagor recommends the following.
• The enclosure must not have any ventilation holes, because they could let dust or other substances
in.
• To improve heat dissipation, install a fan inside the enclosure for air circulation.
Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor
Automation.
i
i
mm
inch
W
390
15.35
H
320
12.60
mm
inch
D
111.5
4.39
e
1.5 - 4
0.06 - 0.16
e
D
H
W
Summary of Contents for CNC 8070
Page 1: ...Ref 1911 8070 CNC Hardware configuration...
Page 8: ...BLANK PAGE 8...
Page 14: ...BLANK PAGE 14...
Page 18: ...BLANK PAGE 18...
Page 22: ...BLANK PAGE 22...
Page 24: ...BLANK PAGE 24...
Page 26: ...BLANK PAGE 26...
Page 28: ...Hardware configuration CNC 8070 1 PREVIOUS INFORMATION 28 REF 1911...
Page 94: ...Hardware configuration CNC 8070 6 CENTRAL UNIT MONITOR Q7 A PLATFORM 94 REF 1911 C70 15AT...
Page 273: ...Hardware configuration CNC 8070 273 User notes REF 1911...
Page 274: ...Hardware configuration CNC 8070 274 User notes REF 1911...
Page 275: ...Hardware configuration CNC 8070 275 User notes REF 1911...