The machine manufacturer must comply with the EN 60204-1 (IEC-204-1) regulation
regarding electrical shocks in case of defective input/output pins with external power supply
when not plugging the connector before turning the power supply on.
Power supply.
• Supply voltage: 24 V DC ±10 % and 3.5 A.
• Current peak of 90 A on power-up.
• Consumption: 85 W (maximum).
Connectivity.
Monitor.
• 1 USB 2.0 port, accessible at the front, protected by a cover.
Central unit.
• 2 USB 1.1 ports (model with a Pentium M processor).
• 4 USB 2.0 ports (models with a T56N processor).
• 1 RS-232/422/485 (115 kbps) serial port.
• 1 LAN RJ45 port for Ethernet 10/100BaseT network.
• 1 VGA output.
• CAN Bus (CANfagor/CANopen).
• Sercos II bus (optional).
• Mechatrolink bus (optional).
• Mouse with PS-2 connector (model with Pentium M processor).
Inputs/outputs.
• 8 digital inputs and 8 digital inputs or outputs (configurable).
- Digital inputs. 24 V DC, 5 mA (typical consumption).
- Digital outputs: 24 V DC, 500 mA.
ON cycle: minimum 75 µs (25 µs, optional in two of them).
• 2 feedback inputs (5 V 0.250 A).
- Incremental differential TTL or differential TTL signal.
- Frequency : 100 kHz (TTL) / 1000 kHz (TTL differential).
• 1 emergency relay with two normally open contacts (1 A at 24 V).
• 2 probe inputs (5 V or 24 V)
• 1 input for three handwheels with A and B signals (5 V DC TTL) (only
C70-10K).
Type.
Description.
Do not get into the inside of the unit. This unit MUST NOT be opened by unauthorized personnel. Only
personnel authorized by Fagor Automation may access the interior of this unit.
Fagor Automation offers several flash compact in its catalog to increase storage space; if you are going
to use other compact flashes, always use industrial grade compact flash SLC; they support
temperatures between -40ºC and +80ºC (-40 ºF and 176 ºF) and last 27 years with 1000 writes per day.
Fagor Automation shall not be held responsible for any problems caused by using other lower-quality
compact flash.
No USB devices must be used nor connected while executing a part program. Using USB devices may
slow down the execution or cause some "RT-IT overflow" type error.
DO NOT connect any kind of hub to the USB port.
Summary of Contents for CNC 8070
Page 1: ...Ref 1911 8070 CNC Hardware configuration...
Page 8: ...BLANK PAGE 8...
Page 14: ...BLANK PAGE 14...
Page 18: ...BLANK PAGE 18...
Page 22: ...BLANK PAGE 22...
Page 24: ...BLANK PAGE 24...
Page 26: ...BLANK PAGE 26...
Page 28: ...Hardware configuration CNC 8070 1 PREVIOUS INFORMATION 28 REF 1911...
Page 94: ...Hardware configuration CNC 8070 6 CENTRAL UNIT MONITOR Q7 A PLATFORM 94 REF 1911 C70 15AT...
Page 273: ...Hardware configuration CNC 8070 273 User notes REF 1911...
Page 274: ...Hardware configuration CNC 8070 274 User notes REF 1911...
Page 275: ...Hardware configuration CNC 8070 275 User notes REF 1911...