Errors 3000-3999
3504
'Acceleration changing speed greater than the maximum'
DETECTION
During startup or execution.
CAUSE
An acceleration changing speed greater than the maximum has been programmed.
SOLUTION
Program a smaller value than the maximum for the speed.
3505
'Jerk limit overshoot'
DETECTION
During execution.
CAUSE
Jerk overshoot on this path.
SOLUTION
Contact your Fagor supplier.
3506
'The Jerk limit will be exceeded'
DETECTION
During the execution of the command to analyze the frequencies.
CAUSE
The frequency is too high for the programmed amplitude.
SOLUTION
Decrease the maximum frequency or decrease the amplitude.
3507
'Acceleration limit exceeded'
DETECTION
During execution.
CAUSE
Too much acceleration on this path.
SOLUTION
Contact your Fagor supplier.
3508
'Frequency too high for the programmed speed'
DETECTION
During the execution of the command to analyze the frequencies.
CAUSE
The additive speed is lower than the one resulting for the maximum frequency.
SOLUTION
Decrease the maximum frequency or program a higher additive speed.
3600
'Zero spindle speed'
DETECTION
During execution.
CAUSE
No spindle positioning speed has been programmed.
SOLUTION
Check the programming and make sure that parameters REFFEED2 and G00FEED
of the active spindle gear are not zero.
3601
'Programmed spindle speed greater than the maximum limit'
DETECTION
During execution.
CAUSE
A spindle speed has been programmed that is greater than the maximum set by
machine parameter for the gear being used.
SOLUTION
Check spindle parameter G00FEED.
3602
'The spindle cannot be moved in DRO mode'
DETECTION
During execution.
CAUSE
Spindle in DRO mode via PLC. DROS = 1 and SERVOSON = 0.
SOLUTION
Check spindle marks DRO and SERVO in the PLC program.
3603
'The commanded spindle position exceeds the module range'
DETECTION
During execution.
CAUSE
An attempt has been made to position the spindle in a coordinate that is out of the
range set by machine parameters MODUPLIM and MODLOWLIM.
SOLUTION
Check parameters MODUPLIM and MODLOWLIM
3604
'Spindle positioning direction contrary to the setting of the machine parameter'
DETECTION
During execution.
CAUSE
A positioning has been programmed that requires a spindle move in the opposite
direction to what has been set by machine parameter UNIDIR.
SOLUTION
Check spindle machine parameter UNIDIR.
3605
'Spindle turning direction contrary to the setting of the machine parameter'
DETECTION
During execution.
CAUSE
A rotation has been programmed that requires a spindle move in the opposite
direction to what has been set by machine parameter UNIDIR.
SOLUTION
Check spindle parameter UNIDIR .
Summary of Contents for CNC8 070
Page 1: ...CNC8070 R EF 0402 ERROR SOLUTIONS...
Page 2: ......
Page 4: ......
Page 6: ......
Page 84: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 78 of 128 Errors 1000 1999...
Page 110: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 104 of 128 Errors 6000 6999...
Page 116: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 110 of 128 Errors 7000 7999...
Page 130: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 124 of 128 Tool and tool magazine table...
Page 133: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 127 of 128...
Page 134: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 128 of 128...