FAGOR supplies the right CHOKE RPS for this application. See the relevant
cable section in table
. Note that the cable must be shielded.
The data for the RPS choke connection terminals is:
WARNING.
Chokes are a must for the operation of a regenerative power
supply. Installing a choke with an inductance other than the one
recommended for a choke may cause severe damage to the unit.
T. H2/31
RPS CHOKE connection terminals. Technical data.
CHOKES
RPS-75-3
RPS-45
RPS-20
Gap (mm)
-
-
10.16
Min./max. tightening torque (N·m)
15
20
6
1.5
Section (mm²)
70
35
10