Power supplies
2.
Ref.1912
· 89 ·
DDS
HARDWARE
The following table shows the values for gap, tightening torque, sections of
the screws and other data of the plug-in connector for X3.
X4 connector
This connector may be used to connect the various modules to each other
through the internal bus communicating with each other the power supply
and all the drives that make up the DDS system.
A ribbon cable is provided with each module ·power supply or drive· for this
connection.
X6 connector
The screwed-on 7-pin Phoenix connector with screw (5.00 pitch) that the
RPS power supply has on its face plate for controlling the module.
NOTE.
It is important to know that if NS1 (pin 3 de X3) and NS2 (pin 4 de
X3) are not short-circuited by the user, the main internal contactor «
LINE
CONTACT
» will stay open. The power supply will start up, but the DC BUS
will not charge and, therefore, the axes cannot move. The status display
may show the warning -
A315
-
indicating that the DC BUS charging time
(SoftStart type) has exceeded the maximum set value because it never
gets charged. Therefore, the main internal contactor «LINE CONTACT»
(pins 3 and 4) MUST BE CLOSED for the system to run.
T. H2/34
Plug-in connector for X3. Technical data.
Connector data
RPS-80 | RPS-75 | RPS-45 | RPS-20
Nr of poles
4
Gap (mm)
5.00
Min./max. tightening torque (N·m)
0.5/0.6
Screw thread
M3
Min./max. section (mm²)
0.2/2.5
Rated current In (A)
12
Wire data
Length to strip (mm)
7
F. H2/46
Connector X4. Internal bus connection between modules.
F. H2/47
Connector X6. Control.
1x
X4
X6 CONNECTOR
Phoenix 5.00 mm
RPS-X
1
2
3
4
ERROR RESET
GND
PWM ENABLE
SYSTEM SPEED
ENABLE
SYSTEM OK
5
6
7
NOT CONNECTED
1
7
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......