Installation Manual - Page: 11
NV-300T/301T Man: 9910 Soft: 2.xx
X3.- SUB-D HD type 15-pin female connector for 1st axis feedback device
(scale or encoder).
X4.- SUB-D HD type 15-pin female connector for 2nd axis feedback device
(scale or encoder).
X5.- SUB-D HD type 15-pin female connector for 3rd axis feedback device
(scale or encoder).
X7.- SUB-D type 9-pin male connector for the RS-232-C (Optional).
This connector as well as the RS232C option are not described here;
but on a supplement for it.
WARNING
Do not handle the connectors while the unit is under power.
Before handling the connectors (mains, feedback, etc.)
make sure that the unit is not under power.
It is NOT enough to turn the display off by using the
key at the keyboard.
1.3
GENERAL CHARACTERISTICS
Universal Power Supply between 100V AC and 240V AC +10% -15%
Mains frequency of 0 Hz (DC) and beteen 45 Hz and 400 Hz
Power outages of up to 20 milliseconds.
10-year memory backup of installation parameters even when the unit is off.
The operating temperature inside the DRO enclosure must be between 5º C
and 45º C (41ºF and 113ºF).
The storage temperature inside the DRO enclosure must be -25º C and +70º
C (-13º F and 158º F).
Maximum relative humidity: 95% non condensing at 45ºC (113ºF).
Front Panel Sealing: IP54 (DIN 40050), Rear panel: IP4X (DIN40050) except
for built-in models in which case is: IP20.