Page: 16 - Installation Manual
NV-300T/301T Man: 9910 Soft: 2.xx
3.1
PARAMETERS TO CONFIGURE AXIS COUNT AND DISPLAY
The digits of digital parameters refer to the digits on the axis displays so digit
"1" corresponds to the rightmost digit and "8" to the leftmost digit.
X
X
X
X
X
X
X
X
8
7
6
5
4
3
2
1
PARA-
METER FUNCTION
PAR00
Feedback configuration, different for each axis. Binary type.
Digit
8
Direction of the coded Io (0 = Increasing, 1 = Decreasing)
7
Pitch of the coded Io (0 = 20 mm, 1 = 100mm)
6
Type of linear scale's Io (0 = Fix, 1 = Coded)
5
Feedback resolution units (0 = microns, 1= inches)
4
Not being used at this time. Must be set to "0".
3
Differential feedback signals (0 = No, 1 = Yes)
The NV-300T model cannto be set to "1" (Yes).
2
Type of feedback signals (0 = TTL, 1 = 1 Vpp)
The NV-300T model cannto be set to "1" (Vpp).
1
Counting direction (0 = normal, 1 = reverse)
If an axis count increases or decreases in the opposite direction to
the one desired, change the value of this digit.