9
Model
FEB-20E
Category
II
2H3P
Type
C
12
,C
32
,C
42
,C
52
kW
23,8
Maximum
Output
kcal/h
20.468
kW
9,3
Central Heating (C.H) Output
Minimum
Output
kcal/h
8.000
kW
23,8
Maximum
Output
kcal/h
20.468
kW
9,3
Domestic Hot Water (D.H.W.) Output
Minimum
Output
kcal/h
8.000
Qn max.
kW
26
Central Heating Nominal Heat Input (Hi) and D.H.W.
Nominal Heat input (Hi)
Qn min.
kW
10,3
D.H.W. Flow Rate at 25º C Temp Rise (l/min)
13,6
D.H.W. Nominal Flow (l/min)
10
Minimum Flow Rate Required to Activate D.H.W. Mode (l/min)
2
Maximum
C.H.
3
Maximum
D.H.W.
10
Operating Pressure (bar)
Minimum
D.H.W.
0,25
Expansion Vessel Capacity (l)
7
Central Heating
60-85
Temperature Selection Range (ºC)
D.H.W. Circuit
35-60
Natural
20
Gas Pressure (mbar)
Propane
37
Natural (m
3
/h)
2,75
Gas Consumption
Propane (kg/h)
2,04
Electrical Supply (V/Hz)
220-230~50Hz
Power Consumption (W)
120
Height
807
Width
440
Dimensions (mm)
Depth
317
Gas Inlet
½”
Cold Water Inlet
½”
Hot Water Outlet
½”
C.H. Flow
¾”
Connections
C.H. Return
¾”
Flue Gas Exit Temp (ºC)
135
Net Weight (kg)
38
3.- TECHNICAL DATA