9
4.6
WATER DRAINAGE
Attach the drain hose as shown in Fig. 5. It is recommended to affix a siphon pipe to prevent odors.
All piping from the machine to the drain must be a minimum 1-1/2” I.P.S. There should also be an air
gap between the machine drain line and the drain. For natural overflow efficiency use floor drain.
4.7
ELECTRICAL CONNECTION
−
To access to the electrical terminal block (R) (Fig. 1), remove the top cover (T) (Fig. 1) and the rear
panel (P) (Fig. 1). Connect the wires as shown in figure 6. Insert the power cord through the cord
holder (E) (Fig. 1) and make sure to leave enough cable to remove the electrical panel from the
front for service. Tighten the connections.
−
Leave free
≥
39” (
≥
1000 mm) of power cord from the rear to facilitate cleaning of the location of
the dishwasher.
−
Install a circuit breaker in accordance to required consumption guidelines and data plate.
−
The machine must be grounded.
WARNING: Electrical Shock Hazard
It is the personal responsibility and obligation of the customer to contact a qualified electrician to
assure that the electrical installation is adequate and is in conformance with the National Electrical
Code, ANSI / NFPA 70 – latest edition and all local codes and ordinance.
2
3/
8"
Fig. 5
D
= Drain hose
C
= Drain collector
A
= Air Gap
F
= Scrap Basket