6 Cabling
MANDATORY.
The installation must comply with Directive EMC 2014/30/EU.
The motor is component to be incorporated on machines. They must comply with
Machine Safety Directive 2006/42/EC and cannot be started up until this directive
is met.
Install the cables safely according to the connection diagrams. Ignoring this
warning may cause the motor to run away and personal injury.
Make sure that the power input is off before doing the installation.
Foresee a protection circuit so the main machine is not connected when the
motor-fan group is not running.
Carry out the right ground connection and electrical noise control (disturbances).
Use the shortest cables possible in the installation. Run the power cables as far
away from the signal cables as possible. Do not run the power cables and the
signal cables through same cable hose or conduit. The noise in signal cables
may cause vibration or poor performance.
Use the cables specified by FAGOR. When using other cables, check the rated
current of the unit and bear in mind the work environment in order to properly
select the cables.