It is essential that the chimney does not get blocked, even partially, for the correct
operation of the burners.
The steps required to optimise the operation of your Fry-Top are shown below, with all the available
options.
5.2.1
Gas fry-top with valve tap
5.2.1.1
Description of the controls
M
– Control M
1
– Ignition pipe
2
– Spark generation unit
CONTROL M
5.2.1.2
Burner ignition
•
Pilot ignition FT-G905 / FT-G910:
o
Turn control M anticlockwise to the position Pilot
and hold button down.
o
Next press the spark generation button. The pilot will light automatically.
o
If the pilot does not light automatically, it is possible to light it manually through the ignition
pipe.
•
Pilot ignition FT-G705 / FT-G710:
o
Turn control M anticlockwise to the position Pilot
and hold button down.
o
Next press the piezo button.
o
If the pilot does not light, it is possible to light it manually through the ignition pipe.
•
Burner ignition:
o
To ignite the burners, press the control and rotate anticlockwise to the required position.
5.2.1.3
Turing the burners off
•
Turn the M control to the position Pilot
, only the pilot will be lit.
5.2.1.4
Turning the pilot light off
•
Turn the M valve control to the Off position .
5.2.2
Gas fry-top with thermostatic valve
Summary of Contents for Kore 700 Series