Digital Brushless AC servo drive system - Ref.0707
MCSi-59/84
Function:
This variable reflects the status of the programmable digital
input at pins 11 and 12 of connector X3. The status of this
variable is affected by IP6.
Valid values:
0 and 1.
Default value:
0.
K group. Monitoring
Function:
Contains the value of power of the external ballast resistor.
Valid values:
200, ..., 2000 W.
Default value:
200 W.
Function:
Contains the value of the energy pulse that can be dissipated
by the external ballast resistor.
Valid values:
200, ..., 2000 J.
Default value:
200 J.
Function:
It displays the temperature of the heatsink of the power stage.
Valid values:
0, ..., 200 °C.
Function:
Variable internally useful to the system. It measures the
internal load level of the calculation of the i
2
t at the drive in
percentage used over the maximum.
Valid values:
0, ..., 100 %.
Default value:
0 %.
IV10 USER, RO DigitalInputs
KP3
USER, RW
ExtBallastPower
KP4
USER, RW
ExtBallastEnergyPulse
KV10
USER, RO
CoolingTemperature
KV32
USER, RO
I
2
tDrive