MCSi-80/84
Digital Brushless AC servo drive system - Ref.0707
LIST OF PARAMETERS,
VARIABLES & COMMANDS.
M
OD
B
US
ID’
S
Mnem.
Name
Level
IdBus
Ac
Min.
Max.
Def.
Units
Page
BV14
NotProgrammableIOs
Fagor
08601
ro
0
65535
-----
-----
CP1
CurrentProportionalGain
Fagor
00213
rw
0
999
-----
-----
CP2
CurrentIntegralTime
Fagor
00215
rw
0
999
-----
-----
CP10
VoltageAmpVolt
user
08823
rw
1000
9999
9500
mV
CP11
AmpAmpVolt
user
08825
rw
100
5000
5000
cA
CP20
CurrentLimit
basic
08807
rw
0
5000
0
cA
CP30
CurrentCommandFilter1Type
Fagor
08809
rw
0
1
0
-----
CP31
CurrentCommandFilter1Frequency
Fagor
08817
rw
0
4000
0
Hz
CP32
CurrentCommandFilter1Damping
Fagor
08819
rw
0
1000
0
Hz
CP45
CurrentCommandSelector
user
08821
rw
0
3
0
-----
CV1
Current1Feedback
user
08811
ro
- 5000
5000
-----
cA
CV2
Current2Feedback
user
08813
ro
- 5000
5000
-----
cA
CV3
CurrentFeedback
user
08815
ro
- 5000
5000
-----
cA
CV10
Current1Offset
Fagor
08803
ro
- 2000
2000
-----
mA
CV11
Current2Offset
Fagor
08805
ro
- 2000
2000
-----
mA
CV15
DigitalCurrentCommand
user
08827
rw
- 5000
5000
0
cA
DC1
ResetClass1Diagnostics
user
00199
rw
0
15
0
-----
DC2
ClearHistoricOfErrorsCommand
user
08997
rw
0
15
0
-----
DV17
HistoricOfErrors
user
09012
ro
-----
-----
-----
-----
DV31
DriverStatusWord
Fagor
00271
ro
0
65535
-----
-----
DV32
MasterControlWord
Fagor
00269
rw
0
65535
0
-----
EP1
EncoderSimulatorPulsesPerTurn
basic
09193
rw
1
pulses
---
-----
EP3
EncoderSimulatorDirection
basic
09197
rw
0
1
0
-----
GC1
BackupWorkingMemoryCommand
basic
00529
rw
0
15
0
-----
GC10
LoadDefaultsCommand
basic
00525
rw
0
15
0
-----
GP3
StoppingTimeout
basic
09597
rw
0
9999
500
ms
GP5
ParameterVersion
basic
09601
ro
----
----
----
-----
GP9
DriveOffDelayTime
basic
00415
rw
0
9999
50
ms
GP11
IOFunctionsTime
user
09645
rw
0
9999
2000
ms
GV2
ManufacturerVersion
basic
00060
ro
----
----
----
-----
GV5
CodeChecksum
basic
09605
ro
----
----
----
-----
GV7
Password
basic
00535
rw
0
9999
0
-----
GV9
DriveType
basic
00280
ro
----
----
----
-----
GV11
SoftReset
basic
09609
rw
0
16
0
-----