background image

QCIG-2/16

Q

uer

C

us SERCOS-II Drive System. 

I

nstallation

 G

uide. Ref.1801/B

Responsibility exemption

The information described in this manual may be subject to
changes due to technical modifications. Fagor Automation
S.Coop. reserves the right to change the contents of this manual
without prior notice.

The content of this manual and its validity for the product described
here has been verified. Nevertheless, the information, technical or
otherwise, in these manuals or in any other type of documentation
is not guaranteed to be integral, sufficient or up to date.

Involuntary errors are possible, hence the absolute match is
guaranteed. However, the contents of manuals and documents are
regularly checked and updated implementing the pertinent
corrections in later editions.

Fagor Automation S. Coop. will not be held responsible for any
losses or damage, direct, indirect or by chance that could result
from that information and it will be the user's responsibility to use it.

Responsibility and warranty claims are excluded in case of
shipping damage, wrong usage of the unit in wrong environments
or when not used for the purpose for which it has been designed,
ignoring the warnings and safety indications given in this document
and/or legal ones that may be applied to the work place,software 

modifications and/or repairs made by unauthorized personnel,
damage caused by the influence of other nearby equipment.

EC Declaration of Conformity and Warranty Terms

The warranty terms may be requested from your Fagor Automation
representative or through the usual commercial channels.
The 

warranty terms

 are available in the downloads section of

FAGOR’s corporate website at, 

http://www.fagorautomation.com

· type of file: General terms and conditions of purchase - warranty 

·

The 

EC Declaration of Conformity

 is available in the downloads

section of FAGOR’S corporate website at,

 

http://www.fagorautomation.com.

 

· type of file: EC Declaration of Conformity ·

Registered trademarks

All registered trade marks, even those not indicated are also
acknowledged. When some are not indicated, it does not mean that
they are free.

January 2018 / Ref.1801/B

All rights reserved. 

No part of this documentation may be

copied, transmitted, transcribed, stored in a backup device or
translated into another language without Fagor Automation’s
permission.

Original instructions. 

Any translation of the original manual

(spanish or english) will replace the phrase ORIGINAL
INSTRUCTIONS with TRANSLATION OF THE ORIGINAL
INSTRUCTIONS.

Full and detailed information.

 

The 

man_qc_pds_hard.pdf

 

manual is available in the downloads

section of FAGOR’s corporate website at

 

http://www.fagorautomation.com

.

DUAL-USE products. 

Products manufactured by Fagor

Automation S. Coop. included on the list of dual-use products
according to regulation (UE) Nr 1382/2014. Their product
identification includes the text -MDU and require an export license
depending on destination.

Summary of Contents for QC-PDS SERCOS-II

Page 1: ...FAGOR AUTOMATION Ref 1801 B QC PDS Installation guide Original instructions FAGOR AUTOMATION DRAFT SERCOS II...

Page 2: ...damage caused by the influence of other nearby equipment EC Declaration of Conformity and Warranty Terms The warranty terms may be requested from your Fagor Automation representative or through the us...

Page 3: ...rning may mean not complying with some safety regulation INFORMATION symbol Notes warnings advises and recommendations Ground protection symbol It indicates that that point must be under voltage i INF...

Page 4: ...tion E21D Direct feedback connection A17 connection terminals of the DC BUS under the lid A18 24 V DC electric power supply input U V W E21D E21 X6 X5 X12 do NOT install X34 do NOT install X13 X1 Vers...

Page 5: ...following radio interference categories EN 61800 3 category C3 4 Dimensions 4 1 Auxiliary power supply QC APSS 15 4 2 Spindle drive QC DR 275 SS2 Connector Function A59 Fan power supply and disconnec...

Page 6: ...data A18 A20 A59 X12 X13 X33 X34 X35 X60 LIM 160 X60 QC RPS Tightening torque min max 0 5 0 6 N m Section 1 mm Screwdriver flat head 0 6x3 5 mm Length to strip 8 mm Tightening torque min max 0 5 0 6 N...

Page 7: ...st reference Storage Ambient temperature Acc to IEC 60721 3 1 IEC 61800 2 1K4 25 C to 60 C Transport Damp heat test steady state Acc to IEC 60068 2 78 IEC 61800 5 1 P supply disconnected 40 C 2 C and...

Page 8: ...ross section of the conductor wires connected to the power supply terminals Comply with local regulations on grounding WARNING The system must always be installed before applying voltage according to...

Page 9: ...order to reduce radiated emissions Use simple shielding for the motor encoder cable The system complies with current regulations regarding immunity with simple shield MANDATORY Installations of large...

Page 10: ...See figure below 373 39 39 78 78 117 78 78 78 78 117 39 77 389 389 467 39 39 39 156 117 78 QC APSS 15 QC DR 275 SS2 QC RPS 160 SN0 LIM 160 39 277 M6 R2 75 M6 39 277 M6 R2 75 M6 152 1 00 464 39 277 99...

Page 11: ...ssories are designed for the purpose of making DC power bus connections between the QC DR 275 SS2 and QC RPS 160 SN0 equipment and tighten the DIN 6923 M10 nuts See figures 1B 2B 1B 2B 24 N m 24 N m 2...

Page 12: ...DC currents This requires the use of a differential breaker Electrical connections Single pole power cables The range of single pole shielded MPC 1xS power cables supplied on request by FAGOR to make...

Page 13: ...minal box and to the grounding plate in the electrical cabinet L1 L2 L3 PE S 2 MPC 1xS MPC 1xS FM9 SPINDLE MOTOR QC APSS 15 QC DR 275 SS2 QC RPS 160 SN0 LIM 160 It is not necessary to remove the lid f...

Page 14: ...m m 2 Sy stem co nnect ion d iagram I n t e r n a l B u s W i r e R i b b o n C a b l e P O W E R D C B U S w i t h Q C R P S 1 6 0 S N 0 I N O U T X 1 X 1 R S 2 3 2 S e r i a l l i n e i n t e r f a...

Page 15: ...D S1 MECHANICAL MAIN SWITCH KM1 GND Q1 DIFFERENTIAL BREAKER EARLY OPEN CONTACT KA3 2 KA3 1 24VDC AT X35 3 RPS ENABLE 24VDC OFF DELAY TIMER KA3 OFF DELAY CONTACT OFF DELAY CONTACT 3x 400 480 VAC FUSES...

Page 16: ...ation Guide Ref 1801 B Code 14460253 Fagor Automation S Coop B San Andr s 19 Apdo 144 E 20500 Arrasate Mondrag n Spain Tel 34 943 719 200 34 943 039 800 Fax 34 943 791 712 E mail info fagorautomation...

Reviews: