Drives
138
3.
DRIVES
Single-dr
ives
· 104 ·
Ref.2003
· 104 ·
QC-PDS
HARDWARE
U1/U, V1/V, W1/W bolts.
Motor power connection
M10 threaded bolts located at the top of the drive and identified as U1/U,
V1/V, W1/W at the top of the plate to supply electrical power to the U, V, W
power phases of the motor, respectively.
QC-DR-275-
FAGOR provides M10 nuts and washers as accessories, but not the
terminals that must be pre-crimped at the end of each MPC-1x
S
single-pole
cable before making the connection for each phase. See the figure.
Pinout
The pinout is printed as U1/U-V1/V-W1/W on the upper part of the of the
front plate of the unit.
Installation
See section,
BRAKELESS FEED AXIS SERVOMOTOR
.
F. H3/36
U1/U-V1/V-W1/W bolts. Connection for the single-pole power cables (1 per
phase) from the spindle motor to the drive.
F. H3/37
U1/U-V1/V-W1/W bolts.
Pinout.
Note.
FAGOR
does not supply the terminals
Single-pole cables
3x 1x150
per phase
Bolts
U1/U
V1/V
W1/W
M10
3x
M10 washers.
M10 nut
DIN 6923
U1/U, V1/V, W1/W
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......