Auxiliary modules
AUXILIARY MODULES
Cho
kes
4.
Ref.2003
· 145 ·
QC-PDS
HARDWARE
Select the relevant CHOKE according to the table for the installed
regenerative power supply.
Installation
See section,
to carry out a proper installation
.
See dimensions
in section,
.
T. H4/6
Selecting the
CHOKE
according to the installed regenerative power
supply.
POWER SUPPLY
CHOKE
QC-RPS-030-F
CHOKE RPS-45
QC-RPS-160-
CHOKE RPS-160
MANDATORY.
A
CHOKE
must always be installed when there is a
regenerative power supply (regulated) ad always placed between the
power supply and the mains filter (after the -
KM1
contactor). The cable
joining the
CHOKE
to the power supply must never exceed two meters in
length and it needs to be shielded.