Selection criteria
5.
S
E
LECT
ING CRI
T
ERIA
Se
lecting
the
main
p
ower
supp
ly
· 192 ·
198
Ref.2003
QC-PDS
HARDWARE
5.5.2
Calculation of the power required from the power supply by the asynchro-
nous motors.
FAGOR asynchronous spindle motor FM7
T. H5/15
Required power drawn from the main power supply by the QC-PDS system when using a FM7...
asynchronous spindle motor. E01|E02.
Note that the highlighted drives appearing in the tables will
be available soon.
Asynchronous
spindle motor
Power (kW)
(%)
Drive power
Drive for
asynchronous
spindle motor
Drive
Pm
S1
S6-40%
S1
S6-40%
(kW)
(%)
(kW)
FM7-A037
3.7
5.5
83.5
83.5
6.6
QC-DR-030
90
7.4
FM7-A055
5.5
7.7
86.0
84.5
9.1
QC-DR-030
90
10.1
FM7-A075
7.5
11.0
86.5
84.6
13.0
QC-DR-030
90
14.4
FM7-A090
9.0
13.0
87.3
85.7
15.2
QC-DR-040
90
16.9
FM7-A110
11.0
15.5
90.2
89.2
17.4
QC-DR-040
90
19.3
FM7-A150
15.0
22.0
90.4
89.3
24.6
QC-DR-055
90
27.4
FM7-B120
12.0
18.5
91.0
90.4
20.5
QC-DR-055
90
22.7
FM7-A185
18.5
26.0
91.8
91.5
28.4
QC-DR-080
90
31.6
FM7-A220
22.0
33.0
89.2
88.1
37.5
QC-DR-120
90
41.6
FM7-B170
17.0
25.0
89.1
87.7
28.5
QC-DR-080
90
31.7
FM7-A300
30.0
45.0
92.1
91.6
49.1
QC-DR-120
90
54.6
FM7-A370
37.0
56.0
92.5
91.7
61.1
QC-DR-160
90
67.9
FM7-B220
22.0
33.0
91.3
90.5
36.5
QC-DR-120
90
40.5
FM7-B280
28.0
42.0
91.1
90.0
46.7
QC-DR-120
90
51.9
FM7-A510
51.0
71.0
92.8
92.2
77.0
QC-DR-160
90
85.6
FM7-C215
21.5
29.0
85.4
82.7
35.1
QC-DR-120
90
39.0
FM7-C270
27.0
37.0
86.6
83.9
44.1
QC-DR-160
90
49.0
FM7 ASYNCHRONOUS SPINDLE MOTORS E01 | E02
Maximum power consumed by the main power supply (kW)
ASYNCHRONOUS
Asynchronous for spindle
Pm
1
2
POWER SUM
(kW)
2
Pm:
Required power drawn for the asynchronous spindle drive in S6-40% cycles.
This data includes the internal losses of the drive. fc: 4 kHz.
where:
Pm
. Maximum power that the drive may demand from the main power supply for each motor-drive
combination. It includes the power dissipated by the drive itself. Units: kW.
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......