Cables
7.
CABLES
SERCOS-III
Interface Eth
ernet Cabl
es
· 226 ·
230
Ref.2003
QC-PDS
HARDWARE
7.5
SERCOS-III Interface Ethernet Cables
7.5.1 QC-FBC-0.25 cable
FAGOR supplies a 0.25 mm curved Ethernet cable that is required to
establish communications via a SERCOS-III digital interface between two
drives (single and/or dual) and also between a drive and the main power
supply if it is regenerative. This QC-FBC-0.25 cable is provided as an
accessory with each device.
There also has a range of QC-FBC-... cables with RJ-45 connectors at
both ends and with lengths ranging from 1 to 100 meters to connect the
Q
UER
C
US
CNC
and is supplied upon request. Available lengths: 1, 2, 3,
5, 7, 10, 12, 15, 20, 25, 30, 35, 40, 50, 60, 75 and 100 meters. See the
following sections for more information.
Installation
See section,
7.5.2 QC-FBC-X cable
SERCOS-III connection cable between a QC-RPS-
-F
main
regenerative power supply and the
Q
UER
C
US
CNC
or between a single
or dual QC-DR-...-F
drive and the
Q
UER
C
US
CNC
.
When the total length of Ethernet cable does not exceed 7 m, use a QC-
FBC-
Ethernet cable.
Characteristics
Installation
See section,
NOTE.
Only available for QC-DR-...-F
models.
NOTE.
Various lengths of the QC-FBC-
cable are supplied upon request
with connectors on their ends.
Reference
QC-FBC-
e approx.
6.3
6.7 mm
Available lengths
1, 2, 3, 5 and 7 m
Type
SERCOS-III industrial cable, type B, shielded.
4 Cat 5 wires (twisted pairs).
Suitable for flexible assemblies.
Color
RAL 6018. Yellowish green.
Flexibility
Minimum static bending radius 3x
e.
Minimum dynamic bending radius 5x
e.
Torsional strength: ± 180 º in 1 meter,
30 000 cycles.
Covering
PVC. Polyvinyl chloride
Permissible
temperature range
Work: -40°C/+70°C (-40°F/158°F)
Storage: -20°C/+60°C (-4°F/140°F)
Connectors
RJ-45, IP 20
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......