Installation
INSTAL
LAT
ION
Ele
ctrica
l co
nne
ctio
ns
8.
Ref.2003
· 279 ·
QC-PDS
HARDWARE
8.5.8
Heat dissipation
External braking resistors can generate a great amount of heat. That's
why, sometimes, depending on the temperature of the installation area, it
may be necessary to evacuate the heat by means of fans.
INFORMATION.
If a fan is required due the conditions of the location of
the installed resistor, remember that FAGOR lists external braking
resistors with a fan in its catalog.
WARNING.
HEAT DANGER. DO NOT TOUCH
the surface of these resistors.
Remember that they can sometimes exceed temperatures of 300°C/572
°F. If it is installed in an easily accessible location, precautions must be
taken to prevent unintentional contact. Also avoid heat sensitive items
(cables, etc.) from coming into contact with the surface to avoid damaging
or destroying these elements and/or causing other more dangerous
situations.
i
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......