QC-PDS
HARDWARE
8.5.11 Connecting the soft-start activation circuit
QC-APS3-15 auxiliary power supply
The control of the soft-start activation is established via the auxiliary
contact of the - KM1 external power contactor and the - KA3 relay contact
controlled by a PLC output. For both, it is possible to supply the +24 V DC
to the internal windings of a relay, via the Da+/Db- terminals of the X33
connector, thus enabling the soft start of the power supply. All information
regarding the
X33 connector
can be found in section,
,
X33 CONNECTOR. SOFT-START CIRCUIT
.
Refer to the diagram in
, pages 5, 12, 14 and 18 of chapter
before making the connection.