The user must configure the QC-RPS-160-
S
N0 power supply with:
1.
The minimum DC BUS voltage required to properly meet the features
required by the system (especially with the needs of the motors installed
and
2.
A voltage setpoint no lower than 1.48 x Vline, approximately.
The possible configuration it offers are:
QC-RPS-160-
S
N0 power supplies will always work in the mode
configured by the switches: either RPS mode or RB6 mode.
·
1
·
RPS operating mode.
Increase to the VP5 voltage value.
The value of
the DC BUS voltage must be approximately that set by the user in
parameter VP5 of the QC-RPS power supply. By default, this value is
650 V DC.
MAX. 725 V DC
.
Select this configuration if
440 V AC
V
line
420 V AC
.
If it cannot properly meet the features required by the system, change the
value of VP5.
·
2
·
RPS operating mode.
Boost to 625 V DC.
The DC BUS voltage is
lower than 625V DC, approx.
Select this configuration if
420 V AC
V
line
400 V AC
. If the features
required by the system are not met, choose another switch configuration
to obtain a higher DC BUS voltage.
·
3
·
RPS operating mode.
Boost to 600 V DC.
The DC BUS voltage is lower
than 600 V DC, approx.
Select this configuration if
V
line
400 V AC
.
If the features required by the system are not met, choose another switch
configuration to obtain a higher DC BUS voltage.
·
4
·
RB6 operating mode.
Maintain 1.41xV
line
.
The voltage value of the
DC BUS will be the rectified value of the mains peak voltage.
Select this configuration if
V
line
440 V AC
. Note, however, that the RB6
operating mode can be configured for any line voltage. If it cannot
satisfactorily meet the features required by the system with this switch
configuration, choose another one.
Configurations
F. H2/30
Selection switches for the DC BUS voltage setpoint. Configurations.
ON
1 2
RPS MODE
RB6 MODE
VP5 V DC
ON
1 2
625 V DC
ON
1 2
600 V DC
ON
1 2
1.41 Vline
Represents the moving element of each switch.
·
1
·
·
2
·
·
3
·
·
4
·
INFORMATION
.
The QC-RPS-160-
S
N0 regenerative power supplies leave
the factory with the switches configured to option 2 (625 V DC).
IMPORTANT.
Make sure software version 01.01 or higher is installed on the power
supply.
i
Meaning
ON
VP5 V DC
ON
625 V DC
ON
600 V DC
ON
1.41 Vline
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......