4.2.2

 

Cleaning the Gasket  

Gaskets  require  regular  cleaning  to  prevent  mold  and  mildew  build  up  and 
also to keep the elasticity of the gasket. Gasket cleaning can be done with 
the  use  of  warm  soapy  water.  Avoid  full  strength  cleaning  products  on 
gaskets as this can cause them to become brittle and prevent proper seals. 

Also, never use sharp tools or knives to scrape or clean the gasket which 
could possibly tear the gasket and rip the bellows. 

Gaskets  can  easily  be  replaced  and  do  not  require  the  use  of  tools  or 
authorized service persons. 

The gaskets can be pulled out of the grove in the door and new gaskets can 
be “pressed” back into place. 

4.2.3

 

Draining the Unit 

Each  unit  has  a  drain  located  inside  the  unit  which  removes  the 
condensation  from  the  evaporator  coil  and  evaporates  it  at  an  external 
condensate  evaporator  pan.  Each  drain  can  become  loose  or  disconnected 
from moving or bumping the drain.  

IF  YOU  NOTICE  EXCESSIVE  WATER  ACCUMULATION  ON  THE  INSIDE  OF  THE 
UNIT  be  sure  the  drain  tube  is  connected  from  the  evaporator  housing  to 
the condensate evaporator drain pan. 

IF WATER IS COLLECTED UNDERNEATH THE UNIT you may want to check the 
condensate  evaporator  drain  tube  to  be  sure  it  is  still  located  inside  the 
drain pan. The leveling of the unit is important as the units are designed to 

drain properly when  on a level surface, if your floor is not level this can 
also  cause  drain  problems.  Be  sure  all  drain  lines  are  free  of 
obstructions;  typically  food  product  is  found  blocking  drain  lines  causing 
water to back up and overflow the drain pans. 

4.3 

 Machine disposal 

The product’s life-cycle is  around 7  to 10 year from the First  use an instalation  
date. 

FAGOR  equipment  is  manufactured    without  dangerous  or    toxic    materials.  Some 
parts of the equipments are biodegradable. 

The disposing  after the product’s life-cycle shall be determined according to the 
rules and laws established in the city or State of residence. 

REMEMBER TO TAKE CARE OF THE ENVIRONMENT. 

 

 

 

 

 

 

 

 

Summary of Contents for QVF-1 N

Page 1: ...MARCH 2017 REFRIGERATORS AND FREEZERS Manual Instructions PREMIUM LINE N Manual instructions Installation and Operation Manual de instrucciones Uso y mantenimiento ES EN DOCUMENT CODE 602305M0063...

Page 2: ...identification label description 7 2 5 Installation and assembly 8 2 6 Connections electrical 8 OPERATION 8 3 1 General information 8 3 2 Control panel description 8 3 2 1 Electronic Control 8 3 3 Ma...

Page 3: ...stalaci n y Ensamble 16 2 6 Conexiones 16 OPERACION 16 3 1 Informaci n General 16 3 2 Descripci n del panel de control 16 3 2 1 Control electronico 16 3 3 Configuraciones del Equipo 17 4 1 Reglas de s...

Page 4: ...___________________________ MODEL HP DIMENSIONS in mm VOLTAGE V AMP A REFRIGERANT CHARGE TIPO REFRIG BTUS HR WEIGHT LB QVR 1 N 1 4 17 x 31 x 80 685 x 675 x 1825 115 220 5 0 3 1 11 3 Oz R 134a 1660 264...

Page 5: ...eaning the condensing unit If machine still running when power is off disconnect power at the circuit breaker before unplugging the machine WARNING Machine and compressor warranties are void if failur...

Page 6: ...that may have occurred during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the deliv...

Page 7: ...tandards If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual 2 4 Manufacturer s identification label description The d...

Page 8: ...onnected to the proper power source Verify correct incoming voltage according to the Data Plate information The data plate in located inside the unit near the top front left corner Under any circumsta...

Page 9: ...decrease the value of the set point for a new temperature press the button DOWN arrow see the picture below Press this button to reach the desired value Release the button and then press the SET butt...

Page 10: ...other vegetables 4 2 1 Cleaning the Condenser Coil Disconnect machine Remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended ev...

Page 11: ...d from moving or bumping the drain IF YOU NOTICE EXCESSIVE WATER ACCUMULATION ON THE INSIDE OF THE UNIT be sure the drain tube is connected from the evaporator housing to the condensate evaporator dra...

Page 12: ...insure proper air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Celsius h Check that the ga...

Page 13: ...ar el mantenimiento reparaci n o limpieza de la unidad condensadora Si la m quina sigue funcionando cuando est apagado desconecte la alimentaci n principal antes de desenchufar la m quina La garant a...

Page 14: ...abra e inspeccione delante de la empresa transportadora todo el equipo Cualquier da o debe ser anotado y reportado en el recibo de entrega de la empresa transportadora IMPORTANTE Una vez que se haya r...

Page 15: ...es relacionadas con el equipo ver la garant a que se encuentra localizada al final del manual 2 4 Placa de identificaci n del Fabricante La placa de datos se encuentra dentro del gabinete cerca de la...

Page 16: ...Conexiones Tome en cuenta los datos sobre el amperaje y voltaje que aparecen en la placa matricula del equipo Es indispensable que la instalaci n el ctrica del usuario cumpla con los requerimientos y...

Page 17: ...evo valor Nota El valor maximo que el control puede mostrar es en refrigeradores 5 C 40 F 3 Si desea disminuir el valor del SET POINT para una nueva temperatura presione el bot n de flecha hacia abajo...

Page 18: ...tos alimenticios de cualquier superficie de acero inoxidable 4 2 1 Limpiando el condensador Desconecte la m quina Quite el panel delantero inferior y cuidadosamente Deslice hacia afuera la unidad cond...

Page 19: ...evaporador Cada drenaje puede ser removido o desconectado Si percibe excesiva acumulaci n de agua en el interior de la unidad aseg rese de que est conectado el tubo de desag e del evaporador a la band...

Page 20: ...ontrol no marque alguna alarma d Verifique que el SET POIT de temperatura es el correcto e Verifique que no existe obstrucci n al flujo del aire en el interior del equipo f Verifique que el ventilador...

Page 21: ...21 fagorindustrial com ELECTRIC DIAGRAM DIAGRAMA ELECTRICO QVR 1_N QVR 2_N...

Page 22: ...22 fagorindustrial com QVR 3_N QVF 1_N...

Page 23: ...23 fagorindustrial com QVF 2_N QVF 3_N...

Page 24: ...24 fagorindustrial com ANEXOS...

Page 25: ...25 fagorindustrial com...

Page 26: ...e Industrial Tres Naciones San Lu s Potos S L P M xico Tel fono Planta S L P 52 444 137 0500 Ext 538 Sin costo 01 800 00 FAGOR MULTI SOLUTION MANUFACTURER OF FOODSERVICE EQUIPMENT 13105 NW 47th Ave Mi...

Reviews: