MAINTENANCE 

4.1 General safety rules. 

4.2 Machine cleaning and maintenance routine. 
4.3 Machine disposal.

 

4.1 

 General safety rules 

 

Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY 
associated with the compressor or cost to replace the compressor! 

Proper  cleaning  of  stainless  steel  requires  soft  cloths  or  plastic  souring  pads. 
Never use steel pads, wire brushes or scrapers! 

4.2 

 Machine cleaning and maintenance routine 

 

Cleaning solutions need to be alkaline or non-chloride cleaners. Any cleaner 
containing chlorides will damage the protective film of the stainless steel. 
Chlorides are also commonly found in hard water, salts, and household and 
industrial cleaners. If cleaner containing chlorides are used be sure to rinse 
repeatedly and dry thoroughly upon completion. 

Routine  cleaning  of  stainless  steel  can  be  done  with  soap  and  water.  Extreme 
stains or grease should be cleaned with a non-abrasive cleaner and plastic scrub 
pad.  There  are  also  stainless  steel  cleaners  available  which  can  restore  and 
preserve the finish of the steels protective layer. 

Never  use  and  acid  based  cleaning  solution!  Many  food  products  have  an  acidic 
content which can deteriorate the finish. Be sure to clean the ALL food products 
from  any  stainless  steel  surface.  Common  items  include  peppers,  tomatoes  and 
other vegetables. 

4.2.1

 

Cleaning the Condenser Coil 

 

Disconnect machine. Remove front bottom panel and carefully slide out the 
condensing unit. 
The  condenser  coil  requires  regular  cleaning;  recommended  every  30-60 
days, depending  of the accumulation of dust and grease.  If the buildup  on 
the  coil  consists  of  only  light  dust  and  debris  the  condenser  coil  can  be 
cleaned with a simple brush. Heavier dust build up may require a vacuum or 
even  compressed  air  to  blow  though  the condenser  coil.  If  heavy  grease is 
present  there  are  de-greasing  agents  available  for  refrigeration  use  and 
specifically  for  the  condenser  coils.  The  condenser  coil  may  require  a 
spray  with  the  de-greasing  agent  and  then  blown  through  with  compressed 
air.  
 
Be sure all  electrical  and  mechanical  parts  are  dry  before  turning  on  the 
power. 
Never use a high pressure water wash for this cleaning procedure as water 
can  damage  the  electrical  components  located  near  or  at  the  condenser 
coil.  Do  not  place  filter  material  in  front  of  condenser  coil.  This  material 
blocks air-flow to the coil similar to having a dirty coil! 
 
If you keep the Condenser  clean you  will  minimize your service expense and 
lower your electrical costs. Failure to maintain a clean condenser coil can 
initially  cause  high  temperatures  and  excessive  run  times.  Continuous 
operation  with  dirty  or  clogged  condenser  coils  can  result  in  compressor 
failures. 
 
To put back the condensing unit in its place, slide in the unit carefully. BE 
SURE DRAIN PIPE IS LOCATED OVER THE PAN. Replace front bottom panel 

 

Summary of Contents for QVR-1 N

Page 1: ...MARCH 2017 REFRIGERATORS AND FREEZERS Manual Instructions PREMIUM LINE N Manual instructions Installation and Operation Manual de instrucciones Uso y mantenimiento ES EN DOCUMENT CODE 602305M0063...

Page 2: ...identification label description 7 2 5 Installation and assembly 8 2 6 Connections electrical 8 OPERATION 8 3 1 General information 8 3 2 Control panel description 8 3 2 1 Electronic Control 8 3 3 Ma...

Page 3: ...stalaci n y Ensamble 16 2 6 Conexiones 16 OPERACION 16 3 1 Informaci n General 16 3 2 Descripci n del panel de control 16 3 2 1 Control electronico 16 3 3 Configuraciones del Equipo 17 4 1 Reglas de s...

Page 4: ...___________________________ MODEL HP DIMENSIONS in mm VOLTAGE V AMP A REFRIGERANT CHARGE TIPO REFRIG BTUS HR WEIGHT LB QVR 1 N 1 4 17 x 31 x 80 685 x 675 x 1825 115 220 5 0 3 1 11 3 Oz R 134a 1660 264...

Page 5: ...eaning the condensing unit If machine still running when power is off disconnect power at the circuit breaker before unplugging the machine WARNING Machine and compressor warranties are void if failur...

Page 6: ...that may have occurred during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the deliv...

Page 7: ...tandards If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual 2 4 Manufacturer s identification label description The d...

Page 8: ...onnected to the proper power source Verify correct incoming voltage according to the Data Plate information The data plate in located inside the unit near the top front left corner Under any circumsta...

Page 9: ...decrease the value of the set point for a new temperature press the button DOWN arrow see the picture below Press this button to reach the desired value Release the button and then press the SET butt...

Page 10: ...other vegetables 4 2 1 Cleaning the Condenser Coil Disconnect machine Remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended ev...

Page 11: ...d from moving or bumping the drain IF YOU NOTICE EXCESSIVE WATER ACCUMULATION ON THE INSIDE OF THE UNIT be sure the drain tube is connected from the evaporator housing to the condensate evaporator dra...

Page 12: ...insure proper air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Celsius h Check that the ga...

Page 13: ...ar el mantenimiento reparaci n o limpieza de la unidad condensadora Si la m quina sigue funcionando cuando est apagado desconecte la alimentaci n principal antes de desenchufar la m quina La garant a...

Page 14: ...abra e inspeccione delante de la empresa transportadora todo el equipo Cualquier da o debe ser anotado y reportado en el recibo de entrega de la empresa transportadora IMPORTANTE Una vez que se haya r...

Page 15: ...es relacionadas con el equipo ver la garant a que se encuentra localizada al final del manual 2 4 Placa de identificaci n del Fabricante La placa de datos se encuentra dentro del gabinete cerca de la...

Page 16: ...Conexiones Tome en cuenta los datos sobre el amperaje y voltaje que aparecen en la placa matricula del equipo Es indispensable que la instalaci n el ctrica del usuario cumpla con los requerimientos y...

Page 17: ...evo valor Nota El valor maximo que el control puede mostrar es en refrigeradores 5 C 40 F 3 Si desea disminuir el valor del SET POINT para una nueva temperatura presione el bot n de flecha hacia abajo...

Page 18: ...tos alimenticios de cualquier superficie de acero inoxidable 4 2 1 Limpiando el condensador Desconecte la m quina Quite el panel delantero inferior y cuidadosamente Deslice hacia afuera la unidad cond...

Page 19: ...evaporador Cada drenaje puede ser removido o desconectado Si percibe excesiva acumulaci n de agua en el interior de la unidad aseg rese de que est conectado el tubo de desag e del evaporador a la band...

Page 20: ...ontrol no marque alguna alarma d Verifique que el SET POIT de temperatura es el correcto e Verifique que no existe obstrucci n al flujo del aire en el interior del equipo f Verifique que el ventilador...

Page 21: ...21 fagorindustrial com ELECTRIC DIAGRAM DIAGRAMA ELECTRICO QVR 1_N QVR 2_N...

Page 22: ...22 fagorindustrial com QVR 3_N QVF 1_N...

Page 23: ...23 fagorindustrial com QVF 2_N QVF 3_N...

Page 24: ...24 fagorindustrial com ANEXOS...

Page 25: ...25 fagorindustrial com...

Page 26: ...e Industrial Tres Naciones San Lu s Potos S L P M xico Tel fono Planta S L P 52 444 137 0500 Ext 538 Sin costo 01 800 00 FAGOR MULTI SOLUTION MANUFACTURER OF FOODSERVICE EQUIPMENT 13105 NW 47th Ave Mi...

Reviews: