TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page
10
seconds. You will see the temperature on the display in °F or °C according to
your selection.
4.2
OTHER FUNCTIONS
Manual Defrost
To select manual defrost, hold the button DOWN arrow for 5 seconds. The snow flake icon
will appear on the display. When this icon is solid it indicates that the equipment is in
Defrost mode.
To exit manual defrost, hold the D OWN button arrow for 5 seconds. The snow flake icon will
turn off. Wait 2 minutes for the compressor to start.
Note:
If the equipment doesn’t reach the temperature, first verify that the defrost cycle is not ON.
The unit will go into defrost every six hours for an average of 20 minutes. The defrost cycle is time initiated and
temperature terminated.
NOTE!
Good air flow inside the cabinet is critical. Do not block air flow to the fans. Allow three inches
of space along the front, back, and sides.
CAUTION!
Do not introduce hot foods, chemical or corrosive products, drugs, or
open beverage bottles.
The unit must run for at least 24 hours before any product is placed inside. Failure to do so
may ice up the evaporator coil. Consequently, the unit will never reach the desired set point.
This failure will not be covered under warranty.