3.3

 

DATA PLATE 

 

The  data  plate  is  located  inside  the  cabinet,  near  the  top  front,  left  corner.  Under  no 
circumstances should the data plate be removed from the unit. The data plate is essential to 
identify  the  particular  features  of  your  machine  and  i t   is  of  great  benefit  to  installers, 
operators, and maintenance personnel. It is recommended that, in the event the data plate is 
removed,  you  copy  down  the  essential  information  in  this  manual  for  reference  before 
installation. Removal of data plate will void the warranty. 
 
 
 
 
 
 
 
 
 
 

 

 
 

3.4

 

LEVELING 

 
Set  unit  in  its  final  location.  A  level  cabinet  looks  better  and  will  perform  better.  Effective 
condensate removal and door operation will be effected by leveling. Machine must be leveled 
front  to  back  and  side  to  side  with  a  level  tool.  Castors  k i t   w i l l   include  shims  for  leveling. 
Insert the shim between the castor and the frame rail. (See installation of castors). Lock front 
castors so cabinet does not move. Ensure drain hose is inside drain pan.  

 

3.5

 

ELECTRICAL CONNECTIONS 

 
Refer  to  the  amperage  data  in  this  manual,  or  on  data  plate,  and  your  local  code  or  the 
National  Electrical  Code  to  be  sure  unit  is  connected  to  the  proper  power  source.  Verify 
correct incoming voltage according to the Data Plate information. 

 

Do  not,  under  any  circumstances,  cut  or  remove  the  ground  prong  from  the  power  cord. 
Fagor units must be properly grounded. 

 

NEVER USE AN EXTENSION CORD! Fagor will not warranty any unit that has been 
connected to an extension cord.

 

 

Fagor  equipment  must  be  grounded  and  connected  in  accordance  with  NEC  Article  422 
Appliances. 
 
 

 

        Model 

 

        Electrical                                                                                                                                      
 
        Refrigerant Type 
 

SERIAL NUMBER FOR 

THE EQUIPMENT 

(8 digits and ends in 

“M”) 

 

Summary of Contents for VTP 139 SL

Page 1: ...TAPAS REFRIGERATOR Manual for installation use and maintenance VTP 139 SL VTP 175 SL...

Page 2: ...IONS 4 3 INSTALLATION 5 3 1 UNCRATING 5 3 2 LOCATION 5 3 3 DATA PLATE 6 3 4 LEVELING 6 3 5 ELECTRICAL CONNECTIONS 6 4 OPERATION 7 4 1 ELECTRONIC CONTROL 7 4 2 OTHER FUNCTIONS 10 5 MAINTENANCE 11 5 1 C...

Page 3: ...al until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines are sec...

Page 4: ...e outlet of the evaporator at 32 C 90 F Model Trays Amps HP Voltage Plug Type BTU Refrigerant charge oz Refrigerant VTP 139 SL 6 2 3 1 6 120 5 15P 850 6 7 134 A VTP 175 SL 9 2 3 1 6 120 5 15P 850 6 7...

Page 5: ...higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to any exte...

Page 6: ...g Machine must be leveled front to back and side to side with a level tool Castors kit will include shims for leveling Insert the shim between the castor and the frame rail See installation of castors...

Page 7: ...ld under any circumstance leave food overnight this will make the evaporator to become frozen and compressor damage may occur Damages caused by leaving the unit ON overnight with product will not be c...

Page 8: ...roller The unit comes with a factory default set point 8 F Freezers 32 F Refrigerators These set values will make the unit perform at its maximum capacity Therefore it is not recommended to change the...

Page 9: ...tton for five 5 seconds until PS is shown in the display Release the button and press the SET button one time Now you will see the number zero 0 With the button UP arrow set a value of 22 and then pre...

Page 10: ...o start Note If the equipment doesn t reach the temperature first verify that the defrost cycle is not ON The unit will go into defrost every six hours for an average of 20 minutes The defrost cycle i...

Page 11: ...deteriorate the stainless steel finish Be sure to clean ALL food products from any stainless steel surface Failure to do so will result in spots and rust on the surface affected 5 1 CLEANING THE CONDE...

Page 12: ...s this can cause them to become brittle and prevent proper sealing Also never use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets c...

Page 13: ...lear the drain pan as necessary to avoid puddles of water underneath the unit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of...

Page 14: ...air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Celsius C h Check that the gasket is in g...

Page 15: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page15 www Fagorcommercial com 7 WIRING DIAGRAMS AUTR 48 60 72 APTS 48 60 72 APTM 48 60 72...

Page 16: ...e replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warranty In...

Page 17: ...unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the right...

Page 18: ...iveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted and rep...

Page 19: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page19 www Fagorcommercial com Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 463 2467 www Fagorcommercial com...