Note:
The maximum value you can set in the controller is: For refrigerators: 5°C (40°F)
For freezers: -16°C (2°F)
3.
If you wish decrease the value of the set point for a new temperature, press the button
DOWN arrow (see the picture below). Press this button to reach the desired value.
Release the button and then press the SET button to keep, and save, the new value.
Note:
The minimum value you can set in the controller is: For refrigerators: -1°C (30°F)
For freezers: -23°C (-8°F)
Changing the reading temperature from °F to °C
To change the reading of the temperature from °F to °C, you need access to the programming
mode in the controller. To do this, press and hold the SET button for five (5) seconds until “PS”
is shown in the display. Release the button and press the SET button one time. Now you will
see the number zero (0). With the button UP arrow, set a value of “22” and then press the SET
button. You will see the “PS” again. Use the button DOWN arrow to find the parameter “EZY”
and press the SET button one time. Using the UP or DOWN button set a value according to the
chart below.
Note:
Freezer equipment can be used like a refrigerator by selecting the value of the parameter “EZY” according to the
chart above. Refrigerators must never be used like a freezer.
After you chose the value for the “EZY” parameter, press and hold the SET button for 5
For Refrigerators
EZY Value
Application
Temperature in °F
3
Refrigeration
Temperature in °C
4
Refrigeration
For Freezers
EZY Value
Application
Temperature in °F
1
Freezer
Temperature in °C
2
Freezer
Temperature in °F
3
Refrigeration
Temperature in °C
4
Refrigeration