background image

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015

 

Page

16

 

www.Fagorcommercial.com

 

 

 

8

 

WARRANTY 

 

 

AS OF APRIL 1, 2014 

 

Three  Years  Parts 

&  Labor  Warranty:  Fagor  Commercial,  Inc.  (“Fagor”)  Warrants  to  the  fist-end-user 

purchaser (the “User”) that the Fagor brand equipment sold hereunder, except for parts and accessories 
which carry the warranty of a supplier (the “Equipment”) will be free from defects in material and factory 
workmanship under normal conditions of use and maintenance and upon proper installation and start-up 
in  accordance  with  the  User  manual  supplied  with  each  Fagor  unit.  The  obligation  of  this  warranty  is 
covered  by  Fagor  for  a  period  of  three  (3)  years  from  the  date of  installation  (Warranty  commencement 
date), but in no event to exceed thirty-nine (39) months from the date of shipment from Fagor. Warranty is 
Not Transferable. 

 

Warranty  Coverage:  If  there  is  a  defect  in  material  or  factory  workmanship  covered  by  this  Warranty 
reported  to  Fagor  during  the  period  the  applicable  Warranty  is  in  force  and  effect,  Fagor  will  repair  or 
replace,  at  Fagor’s  option,  that  part  of  the  Equipment  that  has  become  defective  and  will  cover 
reasonable  labor  cost  within  the  corresponding  warranty  period  of  time. Fagor  shall  bear  all  reasonable 
labor costs in connection with the installation of these replacement parts, provided that, the installation is 
conducted by Fagor or its authorized representative. Charges for warranty travel time round trip, total two 
(2)  hours  or  up  to  100  miles  total.  Any  charges  exceeding  those  stated  herein  must  have  prior 
authorization  by  Fagor.  In  case  Fagor  deems  the  equipment  non-repairable,  said  equipment  will  be 
replaced  and  the  replacement  unit(s)  will  carry  the  same  warranty  period  from  the  original  unit’s 
installation date (original Warranty commencement date).  

 

Additional Two Year Compressor Part Warranty: In addition to the warranty set above, Fagor warrants the 
sealed compressor (part only) for an  additional two (2)  years based on the  original installation date,  but 
not to exceed thirty-nine (39) months after shipment from the manufacturer. This warranty is for defects, 
both in  workmanship and  material, under the  normal and proper use and maintenance service. The two 
(2)  year  extended  warranty  only  applies  to  sealed  parts  of  the  compressor  and  does  not  apply  to  any 
other  part  or  component,  including,  but  not  limited  to  cabinet,  temperature  control,  refrigerant,  motor 
starting equipment, fan assembly, or any other electrical or mechanical component. 

 

 

Exclusions  from  and  Conditions  to  Warranty  Coverage:  This  Warranty  does  not  cover  parts  or 
accessories, which (a) carry the warranty of a supplier or (b) are abused. Application of this Warranty is 
further conditioned upon the following:  

 

 

Installation:  The  Equipment  must  be  properly  installed  in  accordance  with  Fagor’s  installation 
procedures and by a professional technician.  

 

 

No  Alteration:  The  Equipment  must  not  have  been  modified  or  altered  from  its  condition  at  the 
date of original installation.  

 

 

Use:  FAGOR  EQUIPMENT  IS  NOT  DESIGNED  FOR  PERSONAL,  FAMILY,  OR  HOUSEHOLD 
PURPOSES, AND ITS SALE FOR SUCH PURPOSES IS NOT INTENDED. IN THE EVENT THE 
EQUIPMENT  IS  SO  USED,  THIS  WARRANTY  SHALL  BE  NULL  AND  VOID,  AND  THE 
EQUIPMENT  IS  SO  USED,  THIS  WARRANTY  SHALL  BE  NULL  AND  VOID,  AND  THE 
EQUIPMENT SHALL BE DEEMED TO HAVE BEEN SOLD “AS IS-WHERE IS” WITHOUT ANY 
WARRANTY OF ANY KIND, INCLUDING WITHOUT LIMITATION ANY WARRANTY  OF TITLE, 
NON-INFRINGEMENT, MERCHANT-ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

 
 
 

 

 

Summary of Contents for VTP 139 SL

Page 1: ...TAPAS REFRIGERATOR Manual for installation use and maintenance VTP 139 SL VTP 175 SL...

Page 2: ...IONS 4 3 INSTALLATION 5 3 1 UNCRATING 5 3 2 LOCATION 5 3 3 DATA PLATE 6 3 4 LEVELING 6 3 5 ELECTRICAL CONNECTIONS 6 4 OPERATION 7 4 1 ELECTRONIC CONTROL 7 4 2 OTHER FUNCTIONS 10 5 MAINTENANCE 11 5 1 C...

Page 3: ...al until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines are sec...

Page 4: ...e outlet of the evaporator at 32 C 90 F Model Trays Amps HP Voltage Plug Type BTU Refrigerant charge oz Refrigerant VTP 139 SL 6 2 3 1 6 120 5 15P 850 6 7 134 A VTP 175 SL 9 2 3 1 6 120 5 15P 850 6 7...

Page 5: ...higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to any exte...

Page 6: ...g Machine must be leveled front to back and side to side with a level tool Castors kit will include shims for leveling Insert the shim between the castor and the frame rail See installation of castors...

Page 7: ...ld under any circumstance leave food overnight this will make the evaporator to become frozen and compressor damage may occur Damages caused by leaving the unit ON overnight with product will not be c...

Page 8: ...roller The unit comes with a factory default set point 8 F Freezers 32 F Refrigerators These set values will make the unit perform at its maximum capacity Therefore it is not recommended to change the...

Page 9: ...tton for five 5 seconds until PS is shown in the display Release the button and press the SET button one time Now you will see the number zero 0 With the button UP arrow set a value of 22 and then pre...

Page 10: ...o start Note If the equipment doesn t reach the temperature first verify that the defrost cycle is not ON The unit will go into defrost every six hours for an average of 20 minutes The defrost cycle i...

Page 11: ...deteriorate the stainless steel finish Be sure to clean ALL food products from any stainless steel surface Failure to do so will result in spots and rust on the surface affected 5 1 CLEANING THE CONDE...

Page 12: ...s this can cause them to become brittle and prevent proper sealing Also never use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets c...

Page 13: ...lear the drain pan as necessary to avoid puddles of water underneath the unit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of...

Page 14: ...air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Celsius C h Check that the gasket is in g...

Page 15: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page15 www Fagorcommercial com 7 WIRING DIAGRAMS AUTR 48 60 72 APTS 48 60 72 APTM 48 60 72...

Page 16: ...e replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warranty In...

Page 17: ...unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the right...

Page 18: ...iveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted and rep...

Page 19: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page19 www Fagorcommercial com Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 463 2467 www Fagorcommercial com...

Reviews: