TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015

 

Page

7

 

www.Fagorcommercial.com

 

 

 

 

 
 

DANGER:  Power  must  be  turned  off  and  disconnected  from  the  power  source  when  ever 
performing maintenance, repair or cleaning the condensing unit.

 

If machine  is  still running when power is off, disconnect power at the circuit breaker before 
unplugging the machine.

 

 

 

 
 
 

WARNING:  Machine  and  compressor  warranties  are  void  if  failure  is  due  to  improper 
electrical installation.

 

 
 

4

 

OPERATION 

 

The temperature displayed by the electronic controller is the temperature of the evaporator 
of the unit. The temperature of cabinet will be displayed by the analog thermostat provided.  
 
This  display  refrigerator  is design  to  keep  the  product inside  cold,  under  any  circumstance 
leave  food  overnight,  this  will  make  the  evaporator  to  become  frozen  and  compressor 
damage may occur. Damages caused by leaving the unit ON overnight with product will not 
be covered under warranty. 

 

4.1

 

ELECTRONIC CONTROL 

 

After connecting your unit, turn ON rocker switch located next to the controller. The display 
will light up showing the temperature inside the unit. Also, the compressor and fan icons will 
flash for a period of three minutes. After this delay the unit will start cooling.  

 

 
Compressor Icon 

 

Evaporator Fan Icon 
 
Temperature inside the cabinet 

 

 
Verify  you  don't  have  any  alarms  on  the  temperature  controller.  If  after  you  turn  ON  the 
equipment the controller shows t h e  alarm icon or an error code,  call  f o r   technical service. 
They will help you fix the problem. 
 

Note:  The  controller  on  the  equipment  is  programmed  to  display  internal  temperatures  in  Fahrenheit  (°F).  To 

Summary of Contents for VTP 139 SL

Page 1: ...TAPAS REFRIGERATOR Manual for installation use and maintenance VTP 139 SL VTP 175 SL...

Page 2: ...IONS 4 3 INSTALLATION 5 3 1 UNCRATING 5 3 2 LOCATION 5 3 3 DATA PLATE 6 3 4 LEVELING 6 3 5 ELECTRICAL CONNECTIONS 6 4 OPERATION 7 4 1 ELECTRONIC CONTROL 7 4 2 OTHER FUNCTIONS 10 5 MAINTENANCE 11 5 1 C...

Page 3: ...al until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines are sec...

Page 4: ...e outlet of the evaporator at 32 C 90 F Model Trays Amps HP Voltage Plug Type BTU Refrigerant charge oz Refrigerant VTP 139 SL 6 2 3 1 6 120 5 15P 850 6 7 134 A VTP 175 SL 9 2 3 1 6 120 5 15P 850 6 7...

Page 5: ...higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to any exte...

Page 6: ...g Machine must be leveled front to back and side to side with a level tool Castors kit will include shims for leveling Insert the shim between the castor and the frame rail See installation of castors...

Page 7: ...ld under any circumstance leave food overnight this will make the evaporator to become frozen and compressor damage may occur Damages caused by leaving the unit ON overnight with product will not be c...

Page 8: ...roller The unit comes with a factory default set point 8 F Freezers 32 F Refrigerators These set values will make the unit perform at its maximum capacity Therefore it is not recommended to change the...

Page 9: ...tton for five 5 seconds until PS is shown in the display Release the button and press the SET button one time Now you will see the number zero 0 With the button UP arrow set a value of 22 and then pre...

Page 10: ...o start Note If the equipment doesn t reach the temperature first verify that the defrost cycle is not ON The unit will go into defrost every six hours for an average of 20 minutes The defrost cycle i...

Page 11: ...deteriorate the stainless steel finish Be sure to clean ALL food products from any stainless steel surface Failure to do so will result in spots and rust on the surface affected 5 1 CLEANING THE CONDE...

Page 12: ...s this can cause them to become brittle and prevent proper sealing Also never use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets c...

Page 13: ...lear the drain pan as necessary to avoid puddles of water underneath the unit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of...

Page 14: ...air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit g If FREEZER check that the temperature is not Celsius C h Check that the gasket is in g...

Page 15: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page15 www Fagorcommercial com 7 WIRING DIAGRAMS AUTR 48 60 72 APTS 48 60 72 APTM 48 60 72...

Page 16: ...e replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warranty In...

Page 17: ...unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the right...

Page 18: ...iveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted and rep...

Page 19: ...TAPAS CASES SERVICE MANUAL Rev JUN 2015 Page19 www Fagorcommercial com Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 463 2467 www Fagorcommercial com...

Reviews: