background image

FagronLab™ FG – User Manual  |  11

Difficulty to lock the capsules

Capsule are brittle, soft or have static charge

Some capsule are not fall trough the Orienter Tray

9. Extra tips

After seperation the bodies of the capsules are not at the same level with the top sheet of the filler

Filled capsule

Lock

ring

Body 

lock

ring

Reassembled 

capsule

Locked capsule

  Fill weights will not be impacted.

  After capsule separation it is normal that the capsule bodies stay unevenly in the filler.

  There is a slight variation in diameter and height of the capsules. This allows some capsules to fall through to the bottom 

while others are not. 

  Capsules should not stay higher than the top sheet. Use the powder spreader to put them into place before pouring the 

powder.

  After the first tapping the capsule bodies will stay 0.5 to 1 mm lower than the top sheet.

If you face difficulty to fully lock the capsules in the Filler, remove Caps Tray with capsules reassembled. Turn over the Caps 
Tray and press capsules with your thumbs to fully lock them.

Please pay attention that the capsules must be stored and filled  on 15 to 22°C (59 to 72°F) with humidity from 35 to 65%.

Orienter Tray should be pushed 2 or 3 times to allow all the capsules fall through the Orienter Tray. This is caused by the vari-
ation of the capsules diameter, and also by the static charge of the capsule bodies.

FagronLab™ FG

Summary of Contents for FG

Page 1: ...FagronLab FG User Manual www fagronlab com...

Page 2: ......

Page 3: ...ng instructions 7 Orientation 7 Seperation 8 Filling 8 Locking 9 7 Capsule size chart 9 8 Maintenance 10 Cleaning 10 Lubrication 10 9 Extra tips 11 After seperation the bodies of the capsules are not...

Page 4: ...resentative with the following information Serial number Description of problem i e hardware Methods and procedures adopted to resolve the problems Your contact information This device is under warran...

Page 5: ...enter Base available in 100 holes Change parts for each capsule size 00 0 1 2 3 or 4 as needed 99 orientation 100 capsule separation Powder Tray is included to minimize powder loss Lightweight feeder...

Page 6: ...size available 00 0 1 2 3 4 Materials of construction 1 Caps Tray with Locking Plate Metal parts are inox SS304 1 Polycarbonate 2 LDPE 3 Silicone rubber 4 Nylon 2 Body Sheets 2 3 Orienter Tray 4 Space...

Page 7: ...Shake slightly until capsules cover all slots 4 Place feeder locating feet in front holes of Caps Tray Slide Orienter Tray to the left till all capsules drop Re peat the same action by placing feeder...

Page 8: ...om Filler 6 Pull cam lever to secure capsules 8 Release the cam lever so caps fall down into Filler Filling 9 Place the Powder Tray onto Filler 10 Pour powder onto Filler and spread by using Powder Sp...

Page 9: ...pressing down on Locking Plate while pulling up lifting plate 12 Remove Powder Tray Release cam lever if engaged Place Caps Tray onto Filler Capsule size Weight of powder for filling capsule mg Theact...

Page 10: ...C 160 F Handwash Use nylon brushes to clean holes Use household hand dishwashing liquid to clean Do not use solvents or abrasives Cleaning agents Use non aggressive cleaning agents Isopropyl alcohol...

Page 11: ...gh to the bottom while others are not Capsules should not stay higher than the top sheet Use the powder spreader to put them into place before pouring the powder After the first tapping the capsule bo...

Page 12: ...m capsules per batch Use the divider to block empty holes during powder filling Prepare batch sizes in increasements of 10 The kit includes 1 Orienter Divider and 2 Powder Tray Divider Material Inox S...

Page 13: ...FagronLab FG Notes...

Page 14: ...FagronLab FG Notes...

Page 15: ......

Page 16: ...Together we create the future of personalized medicine Fagron Hellas 12 km N R Trikala Larisa P C 42100 P O Box 32 Trikala Greece T 30 24310 83633 5 F 30 24310 83615 www fagron gr F GU M 01...

Reviews: