3.FAILURE CODE
NO
Failure
Code
1
High pressure protection
E1
2
Low pressure protection
E2
3
Abnormal power supply voltage protection
E5
4
Exhaust high temp protection
E8
5
System high temp protection
E9
6
Air out high temp protection
EA
7
Environmental low temp protection
Eb
8
Controller failure
P0
9
Air inlet temperature sensor failure
P1
10
Air outlet temperature sensor failure
P2
11
Exhaust gas temp sensor failure
P3
12
Gas return temp sensor failure
P5
13
Evaporation coil temperature sensor failure
P6
14
Ambient humidity sensor failure
P7
15
Radiator temperature sensor failure
P8
16
Current sensor failure
P9
17
Restart memory failure
PA
18
Compressor drive module or related wiring failure
F1
19
PFC module failure
F2
20
Compressor start failure
F3
21
Compressor running failure
F4
22
Inverter board over current protection
F5
23
Inverter board overheat protection
F6
24
Over current protection
F7
25
Radiator high temperature protection
F8
26
DC fan fault
F9
27
PFC module over current protection
FA