- 1 - 

Warning

 

a.

 

Please read the following tips before installation, use and maintenance. 

b.

 

Installation,  removal  and  maintenance  must  be  carried  out  by  Professional  in 
accordance with the instructions. 

c.

 

Gas leakage test must be done before and after installation. 

 

1. Use 

a.

 

It must be installed or removed by professionals, and it is forbidden to dismantle and 
refit without permission. 

b.

 

Don’t put obstacles before the air inlet and outlet of the heat pump. 

 

2. Installation 

a.

 

This product must be kept away from any source of fire. 
 

 

         
b.

 

The  installation  can’t  be  in  a  closed  environment  or  indoors,  and  must  be  kept  well 
ventilated. 
 

 

 
 
 
 
 
 
 

 

Summary of Contents for Rapid RIC55

Page 1: ...Thank you for choosing Rapid by Fairland Inverter Plus heat pump INSTALLATION USER MANUAL EN CZ DE HR...

Page 2: ......

Page 3: ...nsportation 10 2 Installation and maintenance 10 2 1 Notice before installation 10 2 2 Installation instruction 11 2 3 Trial after installation 14 2 4 Maintenance and winterizing 15 3 Trouble shooting...

Page 4: ...akage test must be done before and after installation 1 Use a It must be installed or removed by professionals and it is forbidden to dismantle and refit without permission b Don t put obstacles befor...

Page 5: ...void sudden acceleration or sudden braking so as to reduce the collision of goods c The unit must be far away from any source of fire d Storage place must be bright wide open and good ventilation vent...

Page 6: ...ollowing components NOTICE Please do not install wrong direction of the water union 1 2 Operating conditions and range ITEMS RANGE Operating range Air temp 7 43 Temp setting heating 18 40 cooling 12 3...

Page 7: ...to heat the pool water It can NEVER be used to heat other flammable or turbid liquid 1 4 2 Don t lift the water union when moving the heat pump since the titanium heat exchanger inside the heat pump w...

Page 8: ...inners paint and fuel to avoid fire 1 4 6 If any abnormal circumstances occurred e g abnormal noises smells smokes and leakage of electricity switch off the main power immediately and contact your loc...

Page 9: ...range Insufficient water flow or pump blocked Power abnormal 2 Operations 2 1 Notice before using For longer service life please ensure water pump is on before heat pump is on and water pump is off af...

Page 10: ...rature Note Screen lock a If no operation in 30 seconds screen will be locked b When HP is off screen will be dark and 0 will be displayed c Press for 3 seconds to lock screen and it will be dark Scre...

Page 11: ...lsory defrosting and will be flashing After defrosting will stop flashing Note Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for more than 10 minutes 6 T...

Page 12: ...power kW at air 15 C 0 13 1 06 0 17 1 2 0 19 1 5 0 23 1 81 0 27 2 2 0 30 2 6 0 36 3 18 0 55 3 8 0 55 3 9 0 61 5 2 Rated input current A at air 15 C 0 56 4 60 0 74 5 2 0 83 6 5 1 00 7 87 1 17 9 6 1 3 1...

Page 13: ...allation and maintenance The heat pump must be installed by a professional team The users are not qualified to install by themselves otherwise the heat pump might be damaged and risky for users safety...

Page 14: ...installers and professionals 11 2 2 Installation instruction 2 2 1 Location and size The heat pump should be installed in a place with good ventilation MINIMUM DISTANCE Filter Water processor Water sw...

Page 15: ...2 2 3 Wiring protecting devices and cable specification Connect to appropriate power supply the voltage should comply with the rated voltage of the products Well earth the heat pump Wiring must be co...

Page 16: ...ide panel Take off the lower half of the panel Unscrew the 3 screws on the cover of the electrical box Connect the terminals according to the electrical diagram A For power supply 230V 50Hz Distributi...

Page 17: ...installation Please check all the wirings carefully before turning on the heat pump 2 3 1 Inspection before use Check installation of the whole heat pump and the pipe connections according to the pipe...

Page 18: ...uble shooting for common faults FAILURE REASON SOLUTION Heat pump doesn t run No power Wait until the power recovers Power switch is off Switch on the power Fuse burned Check and change the fuse The b...

Page 19: ...at cooling mode 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp...

Page 20: ...For installers and professionals 17 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...

Page 21: ...For installers and professionals 18 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...

Page 22: ...For installers and professionals 19 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...

Page 23: ...ls 20 Parallel connection with filtration clock Note The installer should connect A parallel with B as above picture To start the water pump condition A or B is connected To stop the water pump both A...

Page 24: ...For installers and professionals 21 5 Wifi setting 1 APP Download Android mobile please download from iphone please download from 2 Account registration a Registration by Cell phone number Email...

Page 25: ...For installers and professionals 22 b Cell phone number registration 3 Create family Please set family name and choose the room of device...

Page 26: ...lay on the screen once Wifi connection success c If connect fails please make sure your network name and password is correct And your router mobile phone and device are as close as possible d Wifi reb...

Page 27: ...with Heating Cooling function More share devices Indicate the status of Heating Cooling Heating capacity percentage Select The current swimming pool water temperature The setting temperature Timer Sel...

Page 28: ...essionals 25 6 Share devices to your family members After binding if your family members also want to control the device Please let your family members register the APP first and then the administrato...

Page 29: ...1 The weather forecast is just for reference 2 APP is subject to updating without notice The factory reserves the final interpretation right And keep the right to stop or change product specification...

Page 30: ...D kujeme v m e jste si vybrali tepeln erpadlo Rapid s invertorovou technologi Plus od spole nosti Fairland N VOD K INSTALACI A POU IT EN CZ DE HR...

Page 31: ...la n pokyny 12 2 3 Kontrola po instalaci 15 2 4 dr ba a zazimov n 16 3 Odstra ov n b n ch z vad 16 4 K d z vady 17 P loha 1 Sch ma elektrick ho zapojen priority oh evu voliteln 18 P loha 2 Sch ma elek...

Page 32: ...erpadlo mus b t instalov no nebo zlikvidov no odborn ky a je zak z no jednotku demontovat a znovu instalovat kone n m u ivatelem b P edp vodema odvodem vzduchu z tepeln ho erpadla mus b t voln m sto...

Page 33: ...tantn rychlost bez n hl hozrychlen nebo brzd n aby nedo lo k po kozen zbo c Tepeln erpadlo mus b t dostate n vzd leno od mo n ho zdrojepo ru d M sto skladov n mus b t dob ev tr n Vy adov no je odv tr...

Page 34: ...echny n sleduj c d ly D LE ITE Neinstalujte p ipojen vody patn m sm rem 1 2 Provozn podm nky a rozsahy POLO KY ROZSAH Provozn rozsah Teplota vzduchu 7 C 43 C Nastaven teploty topen 18 C 40 C chlazen 1...

Page 35: ...en pro oh ev vody v baz nu NIKDY se nesm pou vat pro oh ev jin ch ho lav ch nebo kaln ch kapalin 1 4 2 Tepeln erpadlo nezvedejte p i p em s ov n za vodn p pojku nebo tak dojde k po kozen titanov ho te...

Page 36: ...ho lav plyny nebo kapaliny jako jsou rozpou t dla barvy a palivo aby nedo lo k po ru 1 4 6 P i jak chkoli neobvykl ch projevech nap klad nenorm ln m hluku z pachu kou i a elektrick m prob jen vypn te...

Page 37: ...ok vody nebo zablokovan ob hov erpadlo Nenorm ln v kon 2 Obsluha 2 1 Upozorn n p ed pou it m Pro zaji t n del ivotnosti pros m ujist te se e erpadlo je zapnut d ve ne se zapne tepeln erpadlo a z rove...

Page 38: ...t Vyberte Smart program nebo Tich program Nahoru Dol Nastaven teploty Pozn mky Uzam en obrazovky a Jestli e nenastane dn aktivita b hem 30ti vte in obrazovka se zamkne b Kdy je tepeln erpadlo vypnut o...

Page 39: ...Topen nastaviteln teplota o rozsahu 18 40 c Chlazen nastaviteln teplota o rozsahu 12 30 4 V b r programu Smart neto Tich Smart program je p ednastaven a bude aktivov n jakmile se tepeln erpadlo zapne...

Page 40: ...ck nap jen tepeln ho erpadla V parn k pros m vy ist te ist c mi prost edky pro dom cnost nebo istou vodou NIKDY nepou vejte benz n rozpou t dla nebo paliva rouby kabely a p pojky pravideln kontrolujte...

Page 41: ...5 0 13 1 06 0 17 1 2 0 19 1 5 0 23 1 81 0 27 2 2 0 30 2 6 0 36 3 18 0 55 3 8 0 55 3 9 0 61 5 2 Jmenovit vstupn proud A p i teplot vzduchu 15 0 56 4 60 0 74 5 2 0 83 6 5 1 00 7 87 1 17 9 6 1 3 11 3 1 5...

Page 42: ...rpadla 2 Instalace a dr ba erpadlo mus b t instalov no profesion ln m t mem U ivatel nejsou opr vn ni prov d t instalaci sami nebo p i tom m e doj t k po kozen tepeln ho erpadla a ohro en bezpe nosti...

Page 43: ...Fro instalat ry a profesion ly 12 2 2 Instala n pokyny 2 2 1 Um st n a rozm ry Tepeln erpadlo mus b t instalovan na m st s dobrou ventilac Minim ln vzd lenost Filtr Vodn procesor Vodn sp na...

Page 44: ...n a specifikace kabel P ipojte k odpov daj c mu elektrick mu nap jen nap t mus odpov dat jmenovit mu nap t za zen Tepeln erpadlo spr vn uzemn te Elektrick zapojen mus b t provedeno profesion ln m tech...

Page 45: ...panelu Uvoln te spodn polovinu panelu Od roubujte 3 rouby na krytu elektrick sk n Svorky p ipojte podle sch matu elektrick ho zapojen A Pro elektrick nap jen 230V 50Hz M stn rozvodn sk nen sou st bale...

Page 46: ...2 3 Kontrola po instalaci P ed zapnut m erpadla pros m pe liv zkontrolujte v echny kabely 2 3 1 Kontrola p ed pou it m Instalaci cel ho tepeln ho erpadla a p ipojen potrub zkontrolujte podle sch matu...

Page 47: ...RAN N Tepeln erpadlo neb Chyb nap jen Po kejte a se obnov dod vka proudu Hlavn sp na je vypnut Zapn te nap jen Sp len pojistka Zkontrolujte a vym te pojistku Vyp na je vypnut Zkontrolujte a zapn te vy...

Page 48: ...vstupn teploty vody 9 P2 Z vada sn ma e v stupn teploty vody 10 P3 Z vada sn ma e v stupn teploty chladiva 11 P4 Z vada sn ma e teploty tepeln ho v m n ku z vada sn ma e teploty v parn ku v re imu chl...

Page 49: ...Fro instalat ry a profesion ly 18 P loha 1 Sch ma elektrick ho zapojen priority oh evu voliteln...

Page 50: ...Fro instalat ry a profesion ly 19 P loha 2 Sch ma elektrick ho zapojen priority oh evu voliteln...

Page 51: ...Fro instalat ry a profesion ly 20 P loha 3 Sch ma elektrick ho zapojen priority oh evu voliteln...

Page 52: ...m filtrace Pozn mka instalat r mus zapojit A paraleln s B podle v e uveden ho obr zku Pro zapnut ob hov ho erpadla je zapojen podm nka A nebo B Pro vypnut ob hov ho erpadla je nutno odpojit A i B A as...

Page 53: ...instalat ry a profesion ly 22 5 Nastaven WiFi 1 Sta en aplikace Android pro mobiln za zen si pros m st hn te z iphone si pros m st hn te z 2 Registrace tu a Registrace podle sla mobiln ho telefonu e m...

Page 54: ...Fro instalat ry a profesion ly 23 b Registrace sla mobiln ho telefonu 3 Vytvo te rodinu Zadejte pros m p jmen a vyberte m stnost za zen...

Page 55: ...e pokyn dokon ete vazbu Po sp n m p ipojen Wi Fi se na obrazovce zobraz c Pokud se p ipojen nezda zkontrolujte pros m spr vn s ov jm no a heslo V sm rova mobiln telefon a za zen jsou co nejbl e d Vrac...

Page 56: ...tepeln erpadlo s funkc topen a chlazen V ce sd let za zen Ozna te stav topen chlazen Topn kapacita procento Vybrat Aktu ln plaveck baz n teplota vody Nastaven teplota Hodiny Vyberte inteligentn Tich...

Page 57: ...esion ly 26 6 Sd lejte za zen se sv mi rodinn mi p slu n ky Po v z n pokud va i lenov rodiny cht j tak ovl dat za zen Pros m nechte sv rodinn p slu n ky nejprve zaregistrovat aplikaci a pot m e admini...

Page 58: ...zn men 1 P edpov po as je pouze informativn 2 Aplikace podl h aktualizaci bez p edchoz ho upozorn n V robce si vyhrazuje pr vo kone n ho v kladu V robce si vyhrazuje pr vo kdykoliv a to i bez p edchoz...

Page 59: ...Vielen Dank dass Sie sich f r die Rapid by Fairland Inverter Plus W rmepumpe entschieden haben INSTALLATIONS UND BENUTZERHANDBUCH EN CZ DE HR...

Page 60: ...chnische Spezifikationen 10 1 Transport 11 2 2 Installationsanweisung 12 2 3 Pr fung nach der Installation 15 2 4 Wartung und Vorbereitungen um die Anlage winterfest zu machen 16 3 Fehlerbehebung f r...

Page 61: ...chleuten installiert und oder entfernt werden Es ist verboten es ohne Erlaubnis zu demontieren oder umzubauen b Stellen Sie keine Hindernisse vor dem Luftein auslass der W rmepumpe auf 2 Installation...

Page 62: ...ieren c Das Ger t muss sich fern von Feuerquellen befinden d Der Lagerort muss hell breit offen und gut bel ftet sein Bel ftungsger te sind erforderlich 4 Wartungshinweis a Wenn eine Wartung oder Repa...

Page 63: ...en Komponenten haben NOTIZ Wasser nicht mit falscher Durchflussrichtung anschlie en 1 2 Betriebsbedingungen und Bereich ELEMENTE BEREICH Betriebsbereich Lufttemp 7 43 Temperatureinstellungen Heizung 1...

Page 64: ...nur verwendet werden um das Poolwasser zu erw rmen Sie sollte nie dazu verwendet werden andere brennbare oder tr be Fl ssigkeit zu erw rmen 1 4 2 Heben Sie den Wasseranschluss nicht an wenn Sie die W...

Page 65: ...igkeiten wie Verd nner Farbe und Kraftstoff um einen Brand zu vermeiden 1 4 6 Wenn ungew hnliche Umst nde auftreten z B Abnorme Ger usche Ger che Rauch und Stromverlust schalten Sie den Hauptschalter...

Page 66: ...e Wasserzufuhr blockiertes schmutziges Pumpensieb Strom nicht normal 2 Betrieb 2 1 Beachten Sie vor der Verwendung Um die Lebensdauer Ihres Ger tes zu verl ngern vergewissern Sie sich vor dem Anschalt...

Page 67: ...Rauf Runter Eingestellte Temperatur anpassen Notiz Bildschirm Sperre a Bildschirmsperre aktiviert sich nach 30 Sekunden selbst b Wenn die W rmepumpe ausgeschaltet ist ist der Bildschirm schwarz und es...

Page 68: ...18 40 c K hlung einstellbarer Temperaturbereich 12 30 4 Smart Silence Modus Auswahl Smart Modus als Standardeinstellung wird bei einschalten des Ger tes mit dem Zeichen angezeigt Dr cken Sie um in den...

Page 69: ...zin Verd nner oder einen hnlichen Brennstoff berpr fen Sie regelm ig die Schrauben Kabel und Anschl sse 2 3 2 Vorbereitungen um die Anlage winterfest zu machen Unterbrechen Sie in der Wintersaison wen...

Page 70: ...eratur 15 0 13 1 06 0 17 1 2 0 19 1 5 0 23 1 81 0 27 2 2 0 30 2 6 0 36 3 18 0 55 3 8 0 55 3 9 0 61 5 2 Nenneingangsstrom A bei Lufttemperatur 15 0 56 4 60 0 74 5 2 0 83 6 5 1 00 7 87 1 17 9 6 1 3 11 3...

Page 71: ...ss von einem professionellen Team installiert werden Der Benutzer ist nicht qualifiziert sie selbst zu installieren da ansonsten die W rmepumpe besch digt werden kann und Sicherheitsrisiken f r den Nu...

Page 72: ...und H ndler 12 2 2 Installationsanweisung 2 2 1 Lage und Gr e Die W rmepumpe sollte an einem Ort mit einer guten Bel ftung installiert werden Mindestabstand Wasseraufbereitungsanlage R ckschlagventil...

Page 73: ...ein Rohr an um das Kondenswasser ableiten zu k nnen 2 2 3 Verkabelung Schutz der Ger te und Kabelspezifikation Schlie en Sie eine passende Stromquelle an Die Spannung sollte mit der Nennspannung des...

Page 74: ...rd der Schwimmbad W rmepumpe Schutzschalter Stromversorgungskabel Stromversorgung 230V 50Hz Stromversorgung 400V 50Hz Erdung B F r Stromversorgung 400V 50Hz Erdung Sicherung L sen Sie mit einem Kreuzs...

Page 75: ...inschalten der W rmepumpe 2 3 1 Inspektion vor Inbetriebnahme berpr fen Sie die Installation der gesamten W rmepumpe und derRohrverbindungen nach der Rohranschlusszeichnung berpr fen Sie die elektrisc...

Page 76: ...r Grund L sung Wasserpumpe startet nicht Kein Strom Warten Sie bis der Strom eingeschaltet wird Hauptschalter ist aus Schalter an der Sicherung durchgebrannt berpr fen Sie ihn und wechseln Sie die Sic...

Page 77: ...ler bei Controller Kommunikation 8 P1 Sensorfehler des Temp Sensors an Wassereinlass 9 P2 Sensorfehler des Temp Sensors an Wasserauslass 10 P3 Sensorfehler des Temp Sensors an Gasauslass 11 P4 Sensorf...

Page 78: ...F r Monteure und H ndler 18 Anhang 1 Schaltplan f r Heizpriorit tsfunktion Optional...

Page 79: ...F r Monteure und H ndler 19 Anhang 2 Schaltplan f r Heizpriorit tsfunktion Optional...

Page 80: ...F r Monteure und H ndler 20 Anhang 3 Schaltplan f r Heizpriorit tsfunktion Optional...

Page 81: ...abelung Wasserpumpe der W rmepumpe A Timer Wasserpumpe Hinweis Der Installateur sollte A parallel zu B wie oben Bild verbinden Um dieWasserpumpe zu starten ist Bedingung dass A oder B verbunden sind U...

Page 82: ...F r Monteure und H ndler 22 5 Wifi Einstellung 1 APP Download iPhone bitte Herunterladen von Android Mobile bitte Herunterladen von 2 Kontoregistrierung a Registrierung per Handynummer E Mail...

Page 83: ...F r Monteure und H ndler 23 b Registrierung der Handynummer 3 Familie erstellen Bitte geben Sie den Namen ein und w hlen Sie den Raum des Ger tes aus...

Page 84: ...fi Verbindung erfolgreich war 3 Wenn die Verbindung fehlschl gt stellen Sie bitte sicher dass Ihr Netzwerkname und Ihr Passwort korrekt sind Des Weiteren sollten Router Mobiltelefon und Ihr Ger t so n...

Page 85: ...unktion Mehr Freigabeger te Zeigt den Status von Heizen K hlen an Prozentsatz der Heizleistung Funktion Heizen K hlen ausw hlen Aush rtungstemperatur aktuelle Wassertemperatur des Schwimmbades Tempera...

Page 86: ...Geben Sie Ger te an Ihre Familienmitglieder weiter wenn Ihre Familienmitglieder auch das Ger t steuern wollen Bitte lassen Sie Ihre Familienmitglieder zuerst das APP registrieren und dann kann der Adm...

Page 87: ...als Referenz gedacht 2 APP kann ohne Vorank ndigung aktualisiert werden Der Hersteller beh lt sich das endg ltige Auslegungsrecht vor Und behaltet Sie sich das Recht vor die Produktspezifikation und...

Page 88: ...Zahvaljujemo to ste odabrali toplinsku crpku Rapid s inverterovom tehnologijom UPUTE ZA INSTALACIJU IKORI TENJE EN CZ DE HR...

Page 89: ...je 11 2 2 Upute za instalaciju 12 2 3 Provjera spajanja nakon instalacije 15 2 4 Odr avanje i zimsko razdoblje 16 3 Otklanjanje uobi ajenih gre aka 16 4 ifra gre ke 17 Prilog 1 Shema elektri nog spaja...

Page 90: ...ti kvalificirana osoba a krajnji korisnik ne smije izvoditi demonta u ili ponovno instaliranje ure aja b Prostor ispred ulaza i izlaza zraka iz toplinske pumpe mora biti slobodan Vi e u uputama 2 Inst...

Page 91: ...nje robe b Toplinska mora mora biti dovoljno udaljena od mogu eg izvora vatre c Mjesto skladi tenja mora biti dobro prozra eno Potreban je ventilacijski ure aj 4 Napomene o odr avanju a Ako je potrebn...

Page 92: ...e NAPOMENA Molimo vas da ne instalirate priklju ke za vodu u pogre nom smjeru 1 2 Uvjeti rada i rasponi Stavke Raspon Radni raspon Temperatura zraka 7 C 43 C Postavljanje temperature grijanje 18 C 40...

Page 93: ...klju ivo za grijanje vode u bazenu NIKADA se ne smije koristiti za grijanje drugih gorivih ili zamu enih teku ina 1 4 2 Ako premje tate toplinsku pumpu ne podi ite je dr e i je za priklju ak vode jer...

Page 94: ...oje i gorivo kako ne bi do lo do po ara 1 4 6 U slu aju bilo kakvihneuobi ajenih okolnosti primjerice neuobi ajene buke mirisa dima iliproboja elektri ne izolacije ure aj odmah isklju ite s mre nog na...

Page 95: ...ri tenja Kako biste produljili ivotni vijek va e t pumpe pobrinite se da pumpa za vodubude uklju ena prije nego to e biti uklju ena toplinska pumpa kao i da toplinska pumpa bude isklju ena prije nego...

Page 96: ...Postavljanje temperature Napomene Zaklju avanje zaslona a Ako nema nikakve aktivnosti tijekom 30 sekundi zaslon se automatski zaklju ava b Kada je toplinska crpka isklju ena zaslon e biti crn i pokaza...

Page 97: ...isnite oznaku a Auto temperatura je postavljena u rasponu od 12 40 b Grijanje temperatura je postavljena u rasponu od 18 40 c Hla enje temperatura je postavljena u rasponu od 12 30 4 Odabir programa S...

Page 98: ...evno odr avanje Molimo ne zaboravite isklju iti elektri no napajanje toplinske crpke Molimo da ispariva istite sredstvom za i enje namijenjenim upotrebi u doma instvima ili istom vodom NIKADA nemojte...

Page 99: ...0 17 1 2 0 19 1 5 0 23 1 81 0 27 2 2 0 30 2 6 0 36 3 18 0 55 3 8 0 55 3 9 0 61 5 2 Nazna ena struja napajanja A na temperaturi zraka od 15 0 56 4 60 0 74 5 2 0 83 6 5 1 00 7 87 1 17 9 6 1 3 11 3 1 57...

Page 100: ...odr avanje T pumputreba instalirati profesionalno obu eno osoblje Korisnici nisu ovla teni za instalaciju budu i da se toplinska crpka mo e o tetiti a postoji i rizik od ugro avanja sigurnosti korisn...

Page 101: ...ere i profesionalce 12 2 2 Upute za instalaciju 2 2 1 Polo aj i dimenzije Toplinska pumpatreba biti postavljena na mjestu s dobrom ventilacijom filter Minimalna udaljenost ventil za protok vode proces...

Page 102: ...a ure aja te specifikacija kabela Spojite na odgovaraju e elektri no napajanje napon treba odgovarati nazna enom naponu ure aja Toplinsku crpku pravilno uzemljite Elektri ne priklju ke treba izvesti o...

Page 103: ...odvija Odvijte tri vijka na ku i tu elektroormari a Stezaljke spojite prema shemi elektri nog spajanja A Za elektri no napajanje 230V 50Hz Razvodna kutija nije dio opreme Kabel za napajanje Elektri no...

Page 104: ...Molimo da prije uklju ivanja ure aja pa ljivo prekontrolirate sve kabele 2 3 1 Kontrola prije kori tenja Instalaciju itave t pumpe i priklju ke cijevi prekontrolirajte prema shemi priklju ka cijevi E...

Page 105: ...nska crpka ne radi Gre ka u mre nom napajanju Sa ekajte dok zapo ne ponovna opskrba strujom Glavni prekida je isklju en Uklju ite mre no napajanje Osigura je pregorio Prekontrolirajte i zamijenite osi...

Page 106: ...temperaturu izlazne vode 10 P3 Gre ka na senzoru ulazne temperature rashladne teku ine 11 P4 Gre ka na senzoru za temperaturu izmjenjiva a topline Gre ka u senzoru za temperaturu ispariva a u re imu...

Page 107: ...Za instalatere i profesionalce 18 Prilog 1 Shema elektri nog spajanja grijanja priority na izbor...

Page 108: ...Za instalatere i profesionalce 19 Prilog 2 Shema elektri nog spajanja grijanja priority na izbor...

Page 109: ...Za instalatere i profesionalce 20 Prilog 3 Shema elektri nog spajanja grijanja priority na izbor...

Page 110: ...najave u bilo koje vrijeme bez odgovornosti za nastale posljedice i nastale obveze Napomena instalater treba priklju iti A paralelno s B prema gore navedenom prikazu Za uklju ivanje cirkulacijske crp...

Page 111: ......

Page 112: ...Version E12Ir32 1...

Reviews: