FR E EZ E CO NTRO L M E N U
This menu determines how the FREEZE control will operate. It
works i n conjunction with the DISPLAY CONTROL menu
selections and the stencil. I f the FREEZE button i s
Off,
the
D i g i ta l path
signal will update certa i n a reas of the field store
defi ned by the stenci l and the OISPLA Y CONTROL selection.
The selection i n the FREEZE CON TROL Me nu gives further
control over how the selected field store a reas are updated. When
the FREEZE button is turned
On,
the updating of the field store
ceases, and so the field store becomes a
frozen
ima ge.
See Section 3
-
OISPLA Y CONTROL Menu for more
information on
display formats
a n d
freezing.
0) Continuous :
This mea ns tha t the digital path input will
con tinuously update t hose field store regions that a r e selected in
the OISPLA
Y
CONTROL menu.
For moving images, the FREEZE button should be
Off.
I f this
button is
O n ,
the image will be still.
1)
Strobe:
This selection freezes a single image at a rate
controlled by the RATE
2
slider.
For example: With RATE
2
nea r the top, i t may be freezing a
single video field every fourth fiel d ; or at the fastest rate of the
RA TE
2
slider, i t will be updating the field store continually
(equivalent to
Con t i n u o us
selection).
N OT E :
Strobe
can also be stopped by the FREEZE button
i n the same ma nner as for
Con t i n uous.
VIDEO MENU
-
SS
Summary of Contents for CVI
Page 1: ...r e User Manual Computer Video Instrument...
Page 4: ...Startea 2 Video Melius...
Page 102: ...33 Quad mirror Slow scan across L J _J...
Page 103: ......
Page 104: ...56 Under over stencil 57 Under over catch up 58 Push to freeze...
Page 105: ...60 L J _JI L...
Page 106: ...80 Under over texture wipe L J _J...
Page 107: ...L J _Jd r...
Page 197: ...RS232C Port ControI 1 Rev 7 Software Update 1...
Page 268: ...Glossary 1 Index 5...
Page 282: ......