Xynergi Media Production Centre
Page 40
downmixed to allow all their members to be monitored in the stereo monitor bus, normal monitor
down mixing occurs between the monitor bus and the selected speaker set.
The AFL solo signal is derived after the feed fader and mute. PFL solo is derived before the feed
fader and mute.
Setup AFL/PFL bus
By default, there is no AFL/PFL bus set up in the system (this saves you from using up 2 bus
elements that you might not need). To create a bus for AFL/PFL:
Step 1
Type
ctrl+SHIFT+U
. The
System Variables
display is shown.
Step 2
Select the checkbox: Allow PFL – reserve stereo buss
Step 3
Click OK
Select Solo Mode
Hold down a
BLUE
key and press the
Utils
key to enter the Utils menu. Press the
{Solo}
soft
key to select the solo system to be used. Unless an ALF/PFL bus has been created, you will not be
able to selected these solo modes.
Soloed feeds are shown with a green indicator on the mixer video display.
Solo Clear
The
Solo Clear
button clears all currently soloed paths, press the
Solo Clear
button again to
restore the soloed channels.
SIP Defeat
Press the
SIP Defeat
key in the Path Configuration section of the Channel Panel to prevent the
selected feed from being muted when other feeds are put into SIP. Alternatively, hold down a
BLUE
key and press the
MUTE
key above any fader to toggle SIP Defeat for that channel. This
feature is useful for keeping reverb returns live when channels feeding them are soloed.
SIP Defeat feeds are shown with a grey solo indicator on the mixer video display.
SIP Defeat is sometimes referred to as Solo Safe.
Naming Inputs and Outputs
Inputs and outputs are named outside the Xynergi application. This is because they are a
permanent fixture in the studio, and it’s best to have their names in a separate file.
WARNING: what follows is a technical operation which can result in loss of resources. Please