____________________________________________________________________________
- 27 -
3.4 Voltage Slew Rate And Current Slew Rate
FTP9000 series power supply supports adjustable voltage and current slew rate, which effectively avoids the
inrush damage or surge damage to the units under test.
Operation:
1. Press
;
2. Select “Set” >> “App Set”, press
to enter the application setting page shown as below:
Set
System
Edit
About
Samp Rate
10Hz
Prio SLT
Volt
V
slew-UP
5000.0 V/s
V
slew-DN
5000.0 V/s
I
slew-UP
2000.0 V/s
I
slew-DN
2000.0 V/s
Figure 3-3 Voltage, Current Slew Rate Set
3. Select parameters to set corresponding value.
3.5 CV/CC Priority Start function
FTP9000 series power supply provides CC priority and CV priority start function, which forces the power supply to
operate in CC or CV mode at the moment the output is turned on, effectively avoids the current or voltage
overshoot resulted from capacitive or inductive load.
Figure 3-4 CV, CC Priority V / I Waveform
Summary of Contents for FTP9000 Series