FAITHTECH
FTB9000 USER MANUAL
45
unlocked state.
Exit the locked state
,
Need to operate again, press
+
button once
more
。
3.13. Sequence function(SEQ)
Sequence output function, menu option is "SEQ", allows users to edit voltage, current
waveform. FTB9000 series devices provide 10 sequence files, each supporting up to 100
running steps. In the running step, voltage setting, current setting and single-step delay
can be set. Support "run times" and "linked files" attributes. "Number of runs" can control
the sequence loop running, set to 0 to indicate an infinite loop. "Link file" adds steps to file
running, set to 0 means no link.
When the sequence is running, the highest voltage, current slope is adopted by
default.
。
Table 3- 4Sequence parameter description table
Parameter
name
Description of parameters
File length
SEQ file running steps, ranging from 1 to 100
Running times
Set the number of sequence file loop runs, ranging
from 0 to 60000, set to 0 for infinite loop, default to 1
Link files
The range of 0 ~ 10, calls the different sequence file to
run this step, set to 0 means no link.
Edit steps
Control which step of the file is currently edited, ranging
from 1 to 100
voltage
The voltage set value of the current step, ranging from
0 to the maximum voltage
Source current
Source current set value for the current step, ranging
from 0 to maximum source current
Source power
Source power set value for the current step, ranging
from 0 to maximum source power
Load current
The load current set value of the current step, ranging
from 0 to the maximum load current
Load power
The load power set value of the current step, ranging