4.Communication introduced
FTB9000 series devices provide users with five kinds of communication interfaces.
Standard USB (serial port), LAN (Ethernet), optional GPIB or CAN, RS485 communication
interface. The communication protocol supports standard Modbus and SCP. The default is
Modbus. Users can select communication interfaces and protocols as required.
4.1.Communication configuration
1. Press
, Enter the menu setting interface
;
2. select“setting”->“system”->“Communication setting”
,
Press
,Pop-up
system parameter Settings interface
;
Photo 4- 1Communication parameter setting interface
3. For LAN communication, the default "IP address" is 192.168.1.123, and the
default "subnet mask" is 255.255.255.0. Secondly, it is necessary to set the IP
address of the computer network connected to it and the IP address of the
device in the same network segment, different IP address, otherwise it will lead
to unsuccessful communication. For example, the computer network IP address
is set to 198.168.1.100.
4. USB serial port communication needs to set the "serial port rate", the default is
9600, support 4800, 9600, 19200, 38400, 115200 Settings. The default of
"Check mode" is "no check".
5. Set Serial Port Rate for the RS485 communication. The default value is 9600,
which can be set to 4800, 9600, 19200, 38400, and 115200. The default of