25
EN
USAGE
Protection Of Extremely
Low & High Temperature
Failures Of Humidity &
Temperature Sensor
Memory Function
If power supply is cut off when the appliance is running, it will
memorize the working mode automatically. Once power
restoration, the appliance will restart and continue this working
mode.
a
)
The appliance will not keep memory function if manual &
timing shutdown, the appliance will restart to run in the
original state, not recover back to the last setted mode.
b
)
When the power supply is shut off in case of protection
mode, the appliance will not recover back to the last setted
mode.
1. When sensor on the air intake detects ambient temperature
≤0°C or ≥40°C, the appliance will shut off automatically for
protection and the beeper continuous warning with 3 long
and 2 short signals.
When sensor detects ambient temperature ≤0°C, 0°C is
showed on the LCD display.
When sensor detects ambient temperature ≥40°C, 40°C is
showed on the LCD display.
2. When sensor on the evaporator detects its temperature ≥
40°C, the appliance will shut off automatically for protection,
and the symbol of automatic defrost illuminates.
a. All function keys are out of functions, you should plug off to
restart the unit.
b. After the protection mode of extremely low & high
temperature, the appliance will not keep its memory
function when restart.
1. When the connect wire of humidity and temperature sensor
breaks off, the symbol of dehumidification will wink, and
“0°C” “0%RH” is showed on the LCD display. The appliance
comes into continuous dehumidifying mode.
a
)
When the temperature sensor malfunctions, the appliance
will turn to continuous dehumidification mode and not under
control of humidity setting.
b
)
This malfunction will not influence the dehumidification.
2. When the temperature sensor of evaporator is open circuit
or short circuit, the symbol of defrost will wink, and the
appliance turns into given dehumidifying and defrosting
mode: dehumidifying for 20 minutes, then defrosting for 5
minutes.
a
)
When the temperature sensor malfunctions, the keys of
control panel will performance normally.
b
)
When the temperature sensor malfunctions, the appliance
will continue to work with lower efficiency.