background image

4

The following diagram shows the overall menu structure of Fakirsmods Illusia-C.

4.

 Menu Overview

The displayed values depend on the operation mode. During temperature controlled vaping, 
the current coil temperature is displayed, the applied power, the wire type, coil resistance 
and the battery charge status (battery symbol). 
Note that all values are permanently updated. Use this feature when you want to check the 
correct operation (just press the fire button with actually vaping, but watch the display). 

Display during/after Vape in TC-Mode 

 

                  Temperature of Coil                     Applied Power              Battery charge status 

 

                    Selected Wire Type            Current Coil Resistance       Voltage with/without power 

 

The following diagram shows the overall menu structure 

                   Main Menu                                   Extended Functions Menu 

 

Summary of Contents for Illusia C

Page 1: ...ILLUSIA C USER MANUAL ...

Page 2: ...ft Button OLED Screen Size 26 mm Output Power 5 60 W Output Current 18 A max Output Voltage 10 V max Single 18650 20700 or 21700 Li ion battery operation 0 91 Inch OLED display Zero current consumption when switched off Temperature controlled vaping mode with various wire types Mechanical MOD mode protected Fakirsmods Illusia C is equipped with Dicodes BF 60 chipset It is an electronically con tro...

Page 3: ...ach vape see display mode setting The displayed values depend on the operation mode During temperature controlled vaping the current coil temperature the applied power the wire type coil resistance and the battery charge status battery symbol is displayed Note that all values are permanently updated Use this feature when you want to check the correct operation just press the fire button with actua...

Page 4: ...lusia C 4 Menu Overview Display during after Vape in TC Mode Temperature of Coil Applied Power Battery charge status Selected Wire Type Current Coil Resistance Voltage with without power The following diagram shows the overall menu structure Main Menu Extended Functions Menu ...

Page 5: ...ey Lock is displayed To unlock the buttons again both buttons need to be pressed at the same time indicated by Key UnLock shown on the display By means of the plus and minus buttons it is possible to navigate through the menu as well as to increase and decrease values of a parameter after a short waiting until the value is displayed inverted black on white The waiting time from navigation mode to ...

Page 6: ...t point for the coil temperature during vaping The temperature set point can be selected from 120 C to 280 C 250 F 540 F in steps of 5 C 10 F To achieve a high precision tempera ture control a correctly performed reference measurement TempCal Init is mandatory see next item This Menu item is only displayed if temperature controlled vaping is selected see Heater Control menu item below For the use ...

Page 7: ...h Other selected the temperature coefficient defined in the Extended Functions Menu under item Tmp Cof is used The value of the selected coefficient is displayed behind Wire For commonly used wires the predefined coefficients are NiFe30 320 Nickel200 620 Ti tanium 350 Tungsten 440 and Stainless Steel 105 Note that there are different alloys for Titanium and Stainless Steel on the market so the pre...

Page 8: ...me In this case different flavors within the liquid which all develop their taste at different temperatures are all addressed by the varying temperature We recommend to set the normal power not the boost to much lower values when using the periodic boost because the average power is increased by the boosts and temperature gets higher therefore Note If the power setting equals the power limit value...

Page 9: ...et voltage would be greater than 10V or the set current would be greater than 20A which depends on the coil resistance For example with a coil resistance of 4 Ohms and a power setting of 40W the required voltage at the coil is 12 7V With 4 Ohms the max imum wattage is 25W 12V 4R 25W Or if the coil resistance is 0 1Ohm the maximum power is 40W because 20A 0 1Ohm 40W As can be seen from the examples...

Page 10: ... rate An initial boost is for quick coil heat up The periodic boost lets the coil temperature pass a certain range all the time In this case different flavors within the liquid which all develop their taste at different temperatures are all addressed by the varying temperature We recommend to set the normal power not the boost to much lower values when using the periodic boost because the average ...

Page 11: ...and temperature gets higher therefore 0 OvrVolt The input voltage is too high The dicodes 2395 is prepared for the use of one or two batteries If the input voltage exceeds 9V this error message is displayed 1 ChkAtom No atomizer detected or open coil 2 TempRef A problem during the temperature reference measurement occurred Repeat the calibration procedure 4 OverCur Short on coil or coil breakdown ...

Page 12: ...Fakirs by email prior to sending back the device If a sent back defective device is not covered by the warranty Fakirs will give the customer a quote for repair before any repair action takes place The postal fee or shipping charge from the customer to Fakirs is not covered by the warranty in any case Warranty does not apply to products purchased through unauthorized vendors The warranty does not ...

Page 13: ...nditions and water Do not drop throw or immerse the device in water Use the proper operating mode according to your atomizer and coil material Do not use this product for other purposes except only for vaping Switch off the device during transport to avoid unintentional firing Do not attempt to repair the product by yourself as damage or personal injury may occur Fakirs Illusia C is a rechargeable...

Page 14: ...www fakirsmods com info fakirsmods com ...

Reviews: