possible via gate (Gateway Z-Wave),
remote control with a display, e.g.
ZRS24 remote control (FAKRO).
2. Calibrate device from controller –
set parameter 12, value 1
Flashing...
-
3. Press UP button and hold it till
reach first end position.
Flashing...
-
4. Press STOP button to confirm first
end position.
Stop flashing and lit
cointinously within 2 sec.
-
5. Press DOWN button and hold it
till reach second end position.
Flashing...
-
6. Press STOP button to confirm
second end position.
Stop blinking and lit
cointinously within 2 sec.
-
4. Association Groups.
There are three association groups in roller shutter ARZ Z-Wave:
1.
Life Line – group for position reporting roller shutter after each a stoppage and alarm reporting (overcurrent, damage
encoders). This group can be a maximum 1 device.
2.
Basic Repeat – group used to transfer the received basic commands to the devices included in this group. This group can be a
maximum 5 devices.
3.
Multilevel Repeat – group used to transfer the received multilevel commands to the devices included in this group. This
group can be a maximum 5 devices.
5. Compatibility of other producers’ appliances in Z-Wave.
Z-Wave allows for the integration of other producers’ appliances for lighting, heating, domestic automatic appliances, etc. The Z-
Wave works in the network as a “repeater”, which enlarges the range of radio communication. The more appliances in the network,
the more resistant to disordered activities in the network.
Launch the “INCLUDE” procedure with a controller of the existing network, and then press the “Programming button” located on the
roller shutter which you want to link to the network.
Attention: All information concerning “Include” and “Associate” options in other producers’ controllers can be found in their
user manuals.
6. Z-Wave configuration parameters.
No.
Value Default Value Size Description
12
1
2
1
1
Value 1 – calibrated
Value 2 – discalibrated – to enter the calibration mode must first time discalibrate and then
calibrate.
13
1
2
1
1
1 – FF go to Max
2 – FF go to previous position
7. Alarms and Notifications.
Notyfication type
Event
Power Management
Over-load detected
System
System hardware failure (encoders damaged)