background image

8. Technical parameters

Technical parameters

Power voltage

15V DC

Rated current

1,4 A

Speed

23 r.p.m

Temperature of usage

(-10

o

C) do (65

o

C)

Supplying cable

2 x 0,75 mm

9. Command classes.

10. Manufacturer Specific Report.

11. Description of signals - light-emitting diode (LED)

Motor operating status (see figure no.1)

Z-Wave operating status (see figure no.1)

Singular blink of the 
diode

The current received from the motor 
is too low. 

Continuous 
lighting   of   the 
diode

The appliance does not belong to any network - 
remove control is impossible.   This diode always 
appears when the appliance is connecting to a new 
motor.  It disappears when the appliance is linked 
to any network using “INCLUDE” function. 

Triple   blink   of   the 
diode

The current received from the motor 
is too intensive. A calibration of the 
roller   shutter   motor   should   be 
checked. A description of outskirts 
regulation is described in point A of 
the roller shutter installation. 

02.03.18 NC817-GB                                                               6/7                                                                ©2018, FAKRO

0x0085
0x0003
0x0011

Manufacturer Specific Report

Parameter

Value

Manufacturer ID
Product Type ID

Product ID

Command Classes

Role

Support

Control

Command Class Z-Wave+ Info v2

ok

Command Class Basic v1

ok

ok

Command Class Version v2

ok

Command Class Manufacturer Specific v2

ok

Command Class Device Reset Locally v1

ok

Command Class Association v2

ok

Command Class Association Group Info v1

ok

Command Class Powerlevel v1

ok

Command Class Switch Binary v1

ok

Command Class Switch Multilevel v3

ok

ok

Command Class Switch All v1

ok

Commad Class Configuration v1

ok

Command Class Notification v3

ok

Command Class Node Naming v1

ok

Summary of Contents for ARZ Z-Wave

Page 1: ...pliances in Z Wave 5 6 Z Wave configuration parameters 5 7 Alarms and Notifications 5 8 Technical parameters 6 9 Command classes 6 10 Manufacturer Specific Report 6 11 Description of signals light emi...

Page 2: ...er mentioned on the rated plate Connect the roller shutter and launch one cycle of work to verify whether it works correctly dual core wire 15V DC Plastic containers used for packing should be kept ou...

Page 3: ...al injury resulting from the contact with moving elements of roller shutter In order to use the appliance it is essential to install it in accordance with the figure manual attached to its package Pro...

Page 4: ...device to the selected group according to user manual supplied with the product Then press the programming button P on the roller shutter for the 1 second Exclude Remove an existed node Exclude This...

Page 5: ...he devices included in this group This group can be a maximum 5 devices 5 Compatibility of other producers appliances in Z Wave Z Wave allows for the integration of other producers appliances for ligh...

Page 6: ...blink of the diode The current received from the motor is too intensive A calibration of the roller shutter motor should be checked A description of outskirts regulation is described in point A of the...

Page 7: ...e appliance was used according to its purpose and in comply with user manual Damage is not an effect of improper power supply installation or an atmospheric conditions The producer is not responsible...