W
Fig.18.
W
- Distance between the ceiling joists.
D1
stringer
D1=D2
D2
header
nails
header
Fig.19.
VIII. INSTALLATION OF THE TEMPORARY SUPPORT BOARDS
Before you begin:
The frame around the ceiling opening must be finished.
STEP 1
Using 4 nails or screws attach the temporary support board 1
Ē
x
4
Ē
x 36
Ē
where the hinged end of the ladder will be installed. This
temporary support board must form a 1/4
Ē
ledge across the
ceiling opening (Figure 20).
Note:
It is recommended to use double headed nails which can be easily
removed.
STEP 2
Using 4 nails or screws, attach the second temporary support at
the other end of the opening so that the temporary support boards
are
ď
X
Ē
inches apart (table 3).
CAUTION:
Check the distance between the temporary support
boards, it must be equal to the values given in table 3 and fig. 20.
The attic ladder can fall down if the temporary support boards are
spaced incorrectly.
MODEL
X - distance between headers
LWS-P 22/47
LWS-P 25/47
46-1/16
Ē
46-1/16
Ē
LWS-P 22/54
LWS-P 25/54
52-7/8
Ē
52-7/8
Ē
Table 3
X
X
temporary
support boards
1/4" ledge along hinged side
screws or nails
Fig.20. Installation of temporary support boards.
X
1/4"
temporary support boards
Installation of stringers
STEP 1
Measure the length of the stringer
ď
W
Ē
between the cross-beams
(Figure18). The measurement should be perpendicular to the headers.
STEP 2
Cut the stringer to size. Use timber similar in size to the existing
ceiling joists.
STEP 3
If the joists do not make up the other two sides of the frame, you
need to install one more stringer of the same length as before. On
Figure 18 only one stringer is needed because the ceiling joist
makes up one side of the frame.
STEP 4
Position the stringer (or stringers) along the unframed side if the
ceiling opening (Figure19). The inside dimensions of the frame
should be equal to the ceiling opening (see product label or table
2 on page 5.
STEP 5
In order to install stringers to the headers you should use nails long
enough to go through both cross-beams and enter the stringer at least
1
Ē
. In most cases it should be 20d nail 4
Ē
long. Square the stringer
and drive 3 nails at each end through the double header. Both
measured dimensions should be within 1/8
Ē
to consider them equal.
9