10.
Now connect the power cable to the hydraulic pump. Put
the cable from the inside of the column to the outside.
Remove the cover on the hydraulic pump and remove the
two wires that protrude from the power unit of the pump.
Loosen the swivel and remove the cable, now put the power
cable through.
11.
230V:
Now secure all wires (1,2 &3, fig.13a) on the correct
positions, as shown in figure 13a and tighten the swivel.
400V:
Now secure all wires as shown in figure 13a and
tighten the swivel.
12.
After connecting the power cable to the pump, it is time to
connect the magnet valve. Check if the signal cable’s red and
blue wire are connected to positions 7 and 17 in the control-
unit, watch step 4.
13.
Loosen the nut which mounts the magnet valve to the pump
and remove the magnet valve. Now loosen bolt 1 (fig.14a)
and remove plastic cover from the magnet valve.
14.
Now loosen the two clamping screws (1, fig.14b) and remove
the blue wires, loosen the swivel and remove the cable with
the two blue wires.
15.
Place the swivel and the cover over the signal cable with red
and blue wire and connect the wires to the magnet valve
using the clamping screws as shown in figure 14c.
16.
Now mount the cover on the magnet valve using bolt 1 (fig.14a), tighten the swivel and place
the magnet valve over the bolt on the pump, secure the valve using the nut.
17.
Now connect the safety locks of column B, make sure to use the wire spring quick connector
clamps, refer to step 5.
18.
Finally the two signal cables protruding from both columns are to be connected. These cables
have to run through the triangular slot in the bottom plate, to prevent the cables from
damaging.
19.
In order to fit the cables through the slot, the plugs (1, fig.15a), 1 male and one female, have
to be disconnected. Use a small flathead screwdriver to put in the recess (2, fig.15a) as
shown in figure 15b. Maneuver the screwdriver until you are able to pull the wire out of the
plug. Now repeat this procedure for the other wire and plug.
Fig.14a
Fig.14b
Fig.14c