23
Flue
Remove the four screws on grill flue that are fixed to
the appliance and the two screws that are fixed to the
removable flue. Offer the removable flue up to the
appliance as diagram ensuring that the removable flue
bottom flange is inside the fixed flue. Secure with the six
screws.
��������������
����������������
����������
�
Installing the flue vent
The flue vent is packed separately.
The larger of the holes along the sides are for screwdriver
access and should face to the rear. Use the screws and
nuts supplied to hold the vent in place.
View from above
Door Handles
Locate the handles over the handle pins with the grub
screw facing downwards whilst holding the handle
firmly against the door. Tighten the grub screws.
Refit the drawer
Rest the drawer back on the side runners and, keeping
it level, push it right back. The clips should click into
position holding the drawer to the side runners. Leave
the levelling tool in the storage drawer, so that the
customer can use it if they wish to move the cooker.
Door adjustment
Please check the aligment of the doors. The oven doors
have adjustible hinges.
To Adjust the Oven Door Angle
The door bottom hinge can be adjusted to alter the
angle of the door.
Loosen the bottom hinge fixing screws and use the
notch and a flat bladed screwdriver to move the position
of the hinge to set the hinge position.