© Allegion 2018
Printed in U.S.A.
640072 Rev. 06/18-e
2. Standard Operation
Upon a legitimate activation signal, the door accelerates to opening speed while monitoring the current load on the drive output. If the
current exceeds the specified level, the door will stop and close.
The door travels at it’s set speed (based on the potentiometer setting) until it reaches the Back Check position, where it will decelerate to
the Back Check Speed.
The door will stop at the Hold Open position and remain there until an activation or the Hold Open Timer is cleared.
The door then closes at its Closing Speed (based on the potentiometer setting) up to the latched position.
If the Closing Speed is decreased by driving the motor in the open direction (a fixed setting), power is added to allow the spring to
continue closing the door to the Full Closed position.
8b Wiring
24VDC +
24VDC -
Electric Lock,
Electric Strike, etc.
Depending on Device
Black DC-
Activation Device
N/O Dry Contacts
Multiple activation devices
should be connected in parallel
Control box
grounding stud
For clarity, not all
components are shown
on the control box PC board
J8, 10-position
Control Box Power Cable
J1, 6-position
Main Power Cable
J5, 2-position
Motor Power Cable
J3, 4-position
Hall Effect Cable
Plug cables into
these receptacles
External
24 VDC
Power Supply
12VAC
12VAC
Safety Sen
Safety GND
Main Act
Main Act Com
Relay N/O
Relay Com
Relay N/C
120VAC
Input
Connect
Fail Safe to Relay N/C
Fail Secure to Relay N/O
Connection to external devices must be made using CL2, CL2P, CL2R, or CL2X Class 2 wire or equivalent.
Summary of Contents for 8230
Page 12: ......